2020
DOI: 10.1016/j.buildenv.2020.107361
|View full text |Cite
|
Sign up to set email alerts
|

Feasibility and limitation of calculative determination of hygrothermal conditions in historical buildings: Case study of st. Martin church in Wiśniowa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 16 publications
(11 citation statements)
references
References 34 publications
0
11
0
Order By: Relevance
“…Such temperature and humidity conditions are conducive to the growth of fungi. Moreover, studies have reported that unsuitable temperature and relative humidity lead to mechanical, biological, and chemical degradation of cultural relics ( Pinzari et al, 2020 ; Sadlowska-Salega and Radon, 2020 ). Currently, heating, ventilation, and air conditioning systems are the main methods used to meet the requirements of heat and humidity ( Ferdyn-Grygierek and Grygierek, 2019 ; Schito et al, 2020 ).…”
Section: Discussionmentioning
confidence: 99%
“…Such temperature and humidity conditions are conducive to the growth of fungi. Moreover, studies have reported that unsuitable temperature and relative humidity lead to mechanical, biological, and chemical degradation of cultural relics ( Pinzari et al, 2020 ; Sadlowska-Salega and Radon, 2020 ). Currently, heating, ventilation, and air conditioning systems are the main methods used to meet the requirements of heat and humidity ( Ferdyn-Grygierek and Grygierek, 2019 ; Schito et al, 2020 ).…”
Section: Discussionmentioning
confidence: 99%
“…It should be noted that the used software was extensively validated for various building typologies and structures. A detailed validation of the hygrothermal WUFI ® plus model can be found in [71,72]. In particular, in a very complex system of boundary conditions, and with a large number of unknowns, it was possible to achieve high compliance of the model with the measurements.…”
Section: Discussionmentioning
confidence: 99%
“…In particular, in a very complex system of boundary conditions, and with a large number of unknowns, it was possible to achieve high compliance of the model with the measurements. Despite the application of well-validated software and carefully defined boundary conditions, no precise reflection of real hygrothermal behaviour of partition could be achieved [72]. However, even in very complex buildings, sufficient model compliance can be achieved:…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Interestingly, [15] presents a multi-objective optimization methodology that guides managers of museums to improve artwork preservation using, in this case, a TRNSYS 17 model [16], where the model becomes a key element to provide insights to the optimization solver. Monitoring and understanding the building through a model becomes a key element enabling analysis of the thermal performance, as well as validations [17] to verify its suitability for containing historical pieces of art.…”
Section: Introductionmentioning