Feasibility Analysis of Solar Power Generation System for Office Building in Academic Institution

Abstract: This paper study the potential of energy-saving through lighting located at the office building in an academic institution known as Politeknik Sultan Azlan Shah (PSAS). Exercise through energy audit has been conducted at 3 main academic building to identify energy usage of lighting. 3 academic building involved is Mechanical Engineering Department (MED), Civil Engineering Department (CED), and the Electrical Engineering Department (EED). This study analysis 5 types of lighting to identify which types of lighti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 10 publications
0
7
0
Order By: Relevance
“…The average peak sun hour in normal conditions is 4-6 hours, as mentioned the [11], while [12] states between 4.0 to 5.4 hours, depending on the location. Despite Malaysia's year-round hot and humid weather, the research's average peak sunlight hours were only calculated to be 4 hours [5,13]. Based on the results of most studies, which indicate that 4 hours is the lowest value, the calculation's reason for choosing this number is grounded in this.…”
Section: Input Setting Of Modification Pv Systemmentioning
confidence: 99%
See 1 more Smart Citation
“…The average peak sun hour in normal conditions is 4-6 hours, as mentioned the [11], while [12] states between 4.0 to 5.4 hours, depending on the location. Despite Malaysia's year-round hot and humid weather, the research's average peak sunlight hours were only calculated to be 4 hours [5,13]. Based on the results of most studies, which indicate that 4 hours is the lowest value, the calculation's reason for choosing this number is grounded in this.…”
Section: Input Setting Of Modification Pv Systemmentioning
confidence: 99%
“…The electricity consumption in Malaysia involves five main sectors known as industry (47.0%), commercial (30.8%), residential (21.6%), agriculture (0.4%), and transport (0.2%) [4]. The commercial sectors focus on research because these sectors are directly related to educational institutions [5]. In 2022, Malaysia currently has 20 public universities with 589,879 students and 31,568 academic staff, while there are 36 polytechnics with 84,556 students and 7,402 academic staff [6].…”
Section: Introductionmentioning
confidence: 99%
“…The number of class day data held based on the PSAS academic calendar year was also collected. Data gathering follows the methodology [8,28,29], where energy audit has been conducted in 4 primary academic departments at PSAS. Most researchers [36][37][38] implement the energy audit methodology to identify which types of equipment consume the highest energy.…”
Section: Data Collection Through the Online System And Auditmentioning
confidence: 99%
“…The estimated annual energy consumption for electrical equipment in the academic building in PSAS can be calculated using the equation ( 1) [8,9,28,29].…”
Section: Mathematical Equationmentioning
confidence: 99%
See 1 more Smart Citation