Feasibility analysis of Earth-Air Heat Exchanger (EAHE) in a sports and culture center in Tianjin, China

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 14 publications
0
5
0
Order By: Relevance
“…The air entering in vertical EAHE at temperature of 257.30 K was found to be, respectively 279.82 K and 267.97 K at pipe outlet for 5⋅10 3 When tab. 8 is examined, it is seen that as the value of Reynolds number increases, the average air temperature values through vertical EAHE length decrease like in horizontal EAHE and there is a temperature difference of 11.85 K between the average air temperature values obtained for the highest and lowest values of Reynolds number at pipe outlet.…”
Section: Heating Performance Of Vertical Eahementioning
confidence: 95%
See 2 more Smart Citations
“…The air entering in vertical EAHE at temperature of 257.30 K was found to be, respectively 279.82 K and 267.97 K at pipe outlet for 5⋅10 3 When tab. 8 is examined, it is seen that as the value of Reynolds number increases, the average air temperature values through vertical EAHE length decrease like in horizontal EAHE and there is a temperature difference of 11.85 K between the average air temperature values obtained for the highest and lowest values of Reynolds number at pipe outlet.…”
Section: Heating Performance Of Vertical Eahementioning
confidence: 95%
“…Despite these results, the average air temperature increases at horizontal EAHE for 4⋅10 4 , 6⋅10 4 , 8⋅10 4 , and 10 5 values of Reynolds number were higher than the average air temperature increases at vertical EAHE outlet. Earth, pipe and air-related temperature contours in vertical EAHE system for 5⋅10 3…”
Section: Heating Performance Of Vertical Eahementioning
confidence: 99%
See 1 more Smart Citation
“…D'Agostino et al [10] revealed that two thermal performance factors for EAHE resulting in good heat transfer: firstly, smaller diameters of the tubes, and secondly a length between 80 and 100 m. Al-Helal et al [11] showed that the EAHE exchanger works in an interesting way at 3 m depth, resulting a remarkable cooling/heating load. The cooling and heating of the EAHE in both winter and summer seasons via a theoretical calculation was analyzed [12]. The different studies in several impacts of an earth-air heat exchanger in semi-arid and arid regions were reviewed [13].…”
Section: Introductionmentioning
confidence: 99%
“…Other tools, as Ansys Fluent [20][21][22], Ansys CFX [23], Comsol Multiphysics [24], Matlab [25][26][27] or Scilab [28] were also used. However, although they offer great possibilities, their use requires specialised knowledge and experience.…”
Section: Introductionmentioning
confidence: 99%