2012
DOI: 10.1016/j.measurement.2011.10.035
|View full text |Cite
|
Sign up to set email alerts
|

FEA calculation of pressure distortion coefficients of gas-operated pressure balances – EURAMET project 1039

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
9
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(9 citation statements)
references
References 6 publications
0
9
0
Order By: Relevance
“…The goal of measuring pressures up to 7 MPa with a relative standard uncertainty of order 1 ppm is a challenge because it requires characterisation of pressure balances with unprecedented accuracy and even significant improvement of the national standard of PTB. For absolute pressure measurements in helium up to 7 MPa, a system of special pressure balances, as outlined in [21,22], was designed, constructed and evaluated [2,[23][24][25]; see also the summary in [9]. The system includes two pressure-balance platforms, three pistoncylinder units (PCUs) with effective areas of 20 cm 2 , and three 2 cm 2 PCUs.…”
Section: Pressure Measurementmentioning
confidence: 99%
“…The goal of measuring pressures up to 7 MPa with a relative standard uncertainty of order 1 ppm is a challenge because it requires characterisation of pressure balances with unprecedented accuracy and even significant improvement of the national standard of PTB. For absolute pressure measurements in helium up to 7 MPa, a system of special pressure balances, as outlined in [21,22], was designed, constructed and evaluated [2,[23][24][25]; see also the summary in [9]. The system includes two pressure-balance platforms, three pistoncylinder units (PCUs) with effective areas of 20 cm 2 , and three 2 cm 2 PCUs.…”
Section: Pressure Measurementmentioning
confidence: 99%
“…For the second goal, it was necessary to characterise pressure balances with an unprecedented quality and even to improve the national standard of PTB significantly. A system of special pressure balances, as outlined in [28,29], was designed, constructed and evaluated [30][31][32][33], see also the summary in [5]. The system includes two pressure-balance platforms, three piston-cylinder units (PCUs) with effective areas of 20 cm 2 and three 2 cm 2 PCUs.…”
Section: Pressure Measurementmentioning
confidence: 99%
“…Although the analytical equations for the effective area provided by Dadson et al are unique, see section 2, the methods of measurement of the PCA's geometries and the numerical procedures vary from laboratory to laboratory. These differences were the topic of comparative studies [16][17][18] that confirmed the generally good agreement and highlighted risky points of the primary characterizations of the PCAs. Of course, a value of the PCA effective area obtained from the model of Dadson et al must be further corrected for thermal and pressure induced changes, see e.g.…”
Section: Introductionmentioning
confidence: 72%
“…Of course, a value of the PCA effective area obtained from the model of Dadson et al must be further corrected for thermal and pressure induced changes, see e.g. [18], but these corrections are not within the scope of this paper.…”
Section: Introductionmentioning
confidence: 99%