Fault Ride Through Capability Improvement of DFIG Based Wind Farms Using Active Power Controlled Bridge Type Fault Current Limiter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

5
0

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…In this portion, the stability and the robustness of the NI-PR controller are accomplished in the presence of symmetrical three lines to ground (3LG) fault and unsymmetrical single line to ground (1LG) fault. Here, 3LG and 1LG faults are considered as 3LG is the most severe and 1LG is the most common fault in power system (Islam et al 2019(Islam et al , 2020a. The faults are considered in the system with a time span of 100 ms (t = 0.22-0.23 s).…”
Section: Performance Against Fault Conditionsmentioning
confidence: 99%
“…In this portion, the stability and the robustness of the NI-PR controller are accomplished in the presence of symmetrical three lines to ground (3LG) fault and unsymmetrical single line to ground (1LG) fault. Here, 3LG and 1LG faults are considered as 3LG is the most severe and 1LG is the most common fault in power system (Islam et al 2019(Islam et al , 2020a. The faults are considered in the system with a time span of 100 ms (t = 0.22-0.23 s).…”
Section: Performance Against Fault Conditionsmentioning
confidence: 99%
“…26 There are several types of NSFCLs, [22][23][24][28][29][30][31][32] which also known as solid-state FCLs (SSFCLs), and bridge-type FCL (BFCL) is one of them. 22,27,33 The BFCL is one of the most commonly used NSFCLs as it provides excellent responses with exceptionally simple structure and extremely easy functioning during grid faults 22,[34][35][36][37][38] and hence, it can be used to improve the transient performance of hybrid power systems.…”
Section: Introductionmentioning
confidence: 99%
“…power system with a SG, PMSG, DFIG, solar PV unit, and battery coupled with the grid via a BFCL switch and simultaneously, activating the shunt impedance path. The detailed operating principle of the BFCL can be found inReferences 22,35. The values of shunt resistor R p and shunt inductor L p are chosen in such a way that they fulfill the condition stated in Reference 22. The parameters of the BFCL are given in Table1.…”
mentioning
confidence: 99%
“…Also, the cooperative control schemes require an appropriate software control algorithm combined with the FCLs to boost the performance of the FCLs. Over the years, different types of controllers have been used with different FCLs [19,21,29,30,32,[37][38][39][40][41][42][43][44]. The controllers can be initially classified into two categories, i.e.…”
Section: Introductionmentioning
confidence: 99%
“…They rely directly on the deviation of different system parameters such as voltage, current, and active power to detect the fault and activate the FCLs. Some of the conventional controllers implemented with different FCLs are discussed in various literature over the years [19, 21, 29, 30, 37].…”
Section: Introductionmentioning
confidence: 99%