2021 IEEE International Conference on Environment and Electrical Engineering and 2021 IEEE Industrial and Commercial Power Syst 2021
DOI: 10.1109/eeeic/icpseurope51590.2021.9584808
|View full text |Cite
|
Sign up to set email alerts
|

Fault detection and localization for T-Type Converter

Abstract: In this paper, an Open-circuit switch fault diagnosis method for a five-level H-Bridge T-type converter is presented. The proposed fault detection method and the fault localization algorithm are based on the switching patterns and the converter output voltage level observation. The proposed fault diagnosis approach is capable to detect and localize an open circuit fault for all switches. The proposed approach is validated by simulations in Matlab Simulink and SimPowerSystem toolbox environments.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 12 publications
0
2
0
Order By: Relevance
“…This paper is an extended version of the conference paper [32] that first introduced the fault diagnosis method for a fivelevel H-Bridge T-Type (5L HB T-Type) converter. Because of the numerous switches that are used in this topology, it is particularly vulnerable to switch faults.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This paper is an extended version of the conference paper [32] that first introduced the fault diagnosis method for a fivelevel H-Bridge T-Type (5L HB T-Type) converter. Because of the numerous switches that are used in this topology, it is particularly vulnerable to switch faults.…”
Section: Introductionmentioning
confidence: 99%
“…When an OCF is declared, the proposed FLA activates the localization process, as well as the identification of the faulty switch, which will be detailed in the following. In [32] the principle parts of the proposed method are presented and validated only with simulation results. In this paper, the OCF diagnosis method is verified and validated by selected experimental results.…”
Section: Introductionmentioning
confidence: 99%