2017
DOI: 10.17559/tv-20160128145656
|View full text |Cite
|
Sign up to set email alerts
|

Fault current due to asynchronous connection of the generator to the grid and impact on HV circuit breaker with gas SF6

Abstract: Original scientific paperThe description and analysis of phenomena that occur in case of disconnection of fault currents with generator circuit breakers after asynchronous connection of a generator and difficulties encountered during the process of disconnection are given in the paper. Generally, the biggest problems occur during the interruption of the fault when the direct current component (DC) is very high. DC component value depends on the type and conditions of the fault. For this purpose, a real study c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(3 citation statements)
references
References 4 publications
0
3
0
Order By: Relevance
“…A single line diagram of the simulation network with EMTP-ATP is shown in Figure 14. The equivalent model provides good results, as can be seen by comparing Figure 5 (real event) with Figures 7-9 (obtained through simulations) [14,[25][26][27].…”
Section: Resultsmentioning
confidence: 68%
See 1 more Smart Citation
“…A single line diagram of the simulation network with EMTP-ATP is shown in Figure 14. The equivalent model provides good results, as can be seen by comparing Figure 5 (real event) with Figures 7-9 (obtained through simulations) [14,[25][26][27].…”
Section: Resultsmentioning
confidence: 68%
“…To validate the power network model, a simulation was used for the same phase angle of 114 • (angle of 114 • has been taken from the SIEMENS digital relays data), under which the activation of a non-synchronized generator in the network occurred. The simulations of these cases are given in Figures 7-12 [14,[23][24][25].…”
Section: Resultsmentioning
confidence: 99%
“…Kolarik presented the operation principle of admittance protection, calculation, and recommendation for activating admittance protection for 20 kV feeders in a system with low-ohmic and parallel compensation grounding [16]. Alidemaj et al analyzed the performance of the circuit breaker during the disconnection of the failure currents due to the asynchronous connection of the generator on the grid and emphasized the importance of studying the network for each specific case for dimensioning of generator breakers [17]. Nikolovski et al presented a procedure and computation of relay protection coordination for a photovoltaic power plant connected to the distribution network [18].…”
Section: Introductionmentioning
confidence: 99%