Fatigue of Dental Implants: Facts and Fallacies

Abstract: Dental implants experience rare yet problematic mechanical failures such as fracture that are caused, most often, by (time-dependent) metal fatigue. This paper surveys basic evidence about fatigue failure, its identification and the implant’s fatigue performance during service. We first discuss the concept of dental implant fatigue, starting with a review of basic concepts related to this failure mechanism. The identification of fatigue failures using scanning electron microscopy follows, to show that this sta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
43
0
2

Year Published

2017
2017
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 43 publications
(50 citation statements)
references
References 26 publications
(27 reference statements)
2
43
0
2
Order By: Relevance
“…The Dental implants are subjected to variable loads during their life span due to mastication or other reasons, as bruxism for example, which may lead to structural failure due to fatigue [7]. In fact, clinical studies report that the vast majority of implant restoration mechanical failures are caused by fatigue [8]. These failures can take place in the abutment, in the implant body or in the prosthetic screw depending on implant diameter, load case, implant position, etc.…”
Section: Introductionmentioning
confidence: 99%
“…The Dental implants are subjected to variable loads during their life span due to mastication or other reasons, as bruxism for example, which may lead to structural failure due to fatigue [7]. In fact, clinical studies report that the vast majority of implant restoration mechanical failures are caused by fatigue [8]. These failures can take place in the abutment, in the implant body or in the prosthetic screw depending on implant diameter, load case, implant position, etc.…”
Section: Introductionmentioning
confidence: 99%
“…Coils may be present or not [30,31,32,33,34,35,36,37,38,39,40]. The function of the loops is to efficiently distribute the masticatory load and to guarantee stability in the early post-surgical phases of the implant [41,42,43]. On the other hand, secondary or surface geometries are the basis of the osseointegration potential of the implant.…”
Section: Methodsmentioning
confidence: 99%
“…The fatigue testing consisted of random spectrum loading, a technique that has been exposed in detail previously [27,29,30] so that it will only be briefly detailed here. The main idea is to apply random loading cycles in a range of selected loads (P) from 0 to Pmax, at frequencies that vary from 0 Hz (pause of variable duration) up to 3 Hz.…”
Section: Methodsmentioning
confidence: 99%