2018
DOI: 10.1016/j.cej.2018.06.035
|View full text |Cite
|
Sign up to set email alerts
|

Fate of sulfadiazine and its corresponding resistance genes in up-flow microbial fuel cell coupled constructed wetlands: Effects of circuit operation mode and hydraulic retention time

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 97 publications
(9 citation statements)
references
References 59 publications
0
9
0
Order By: Relevance
“…For the average COD concentration in the reactor is decreased (Ma et al 2016). The higher the HRT, the greater the microbial diversity (HaiLiang et al 2018). It is worth mentioning that retention time and flow rate are inversely related to each other.…”
Section: Flow Rate and Hydraulic Retention Timementioning
confidence: 99%
“…For the average COD concentration in the reactor is decreased (Ma et al 2016). The higher the HRT, the greater the microbial diversity (HaiLiang et al 2018). It is worth mentioning that retention time and flow rate are inversely related to each other.…”
Section: Flow Rate and Hydraulic Retention Timementioning
confidence: 99%
“…CW-MFC was also used in the treatment of PPCPs in wastewater, including sulfadiazine, sulfamethoxazole, tetracycline, etc. [28][29][30]. It was found that the removal performance of CBZ in CW-MFC system was better than that of CW system [31].…”
Section: Introductionmentioning
confidence: 95%
“…Up to date, there are only a few publications dealing with the use of CW-MFC for OMP removal, and to the authors' knowledge, there are none on the use of CW-MEC systems. Generally, CW-MFC systems have been described to increase the microbial activity (determined by means of fluorescein diacetate (FDA) hydrolysis) in CW-MFC (Hartl et al, 2019), and some studies showed that CW-MFC enhance microbial community richness and diversity as compared to an open-circuit control (Song et al, 2018;F. Xu et al, 2018a).…”
Section: Introductionmentioning
confidence: 99%
“…Generally, CW-MFC systems have been described to increase the microbial activity (determined by means of fluorescein diacetate (FDA) hydrolysis) in CW-MFC (Hartl et al, 2019), and some studies showed that CW-MFC enhance microbial community richness and diversity as compared to an open-circuit control (Song et al, 2018;F. Xu et al, 2018a).…”
Section: Introductionmentioning