2000
DOI: 10.1007/bf02491570
|View full text |Cite
|
Sign up to set email alerts
|

Fast supercritical fluid chromatography of polymers using packed capillary columns

Abstract: SummaryFast separations of perfluorinated polyethers and polymethylsiloxanes that are composed of 50-80 ohgomers were demonstrated in packed capillary column supercritical fluid chromatography (SFC) using a carbon dioxide mobile phase. Separations were accomplished within 10 min using a 13 cm x 250 I~m i.d. column packed with 2 I~m porous octadecyl bonded silica (ODS) particles. Effects of particle diameter of the packing material and pressure programming on separation were investigated, and packed column SFCw… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2001
2001
2019
2019

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(4 citation statements)
references
References 22 publications
0
3
0
1
Order By: Relevance
“…Wu et al used packed-capillary-column SFC to separate perfluorinated polyethers and polymethylsiloxane oligomers with CO 2 mobile phase (34). Decreasing the particle size and the column length in concert, ultimately to 2 µm and 13 cm, respectively, led to a 7-fold reduction in analysis time while maintaining resolution between the peaks.…”
Section: Mobile Phases and (Achiral) Stationary Phasesmentioning
confidence: 99%
“…Wu et al used packed-capillary-column SFC to separate perfluorinated polyethers and polymethylsiloxane oligomers with CO 2 mobile phase (34). Decreasing the particle size and the column length in concert, ultimately to 2 µm and 13 cm, respectively, led to a 7-fold reduction in analysis time while maintaining resolution between the peaks.…”
Section: Mobile Phases and (Achiral) Stationary Phasesmentioning
confidence: 99%
“…Neste caso, a cromatografia de permeação em gel (GPC, "gel permeation chromatography") é utilizada, mas não é tão precisa. Por esta razão, a cromatografia com fluido supercrítico é a única alternativa nestes casos, separando os oligômeros individuais e permitindo, inclusive, sua quantificação [49][50][51] .…”
Section: Polímerosunclassified
“…SFC separation times can be further reduced using methods similar to those used to decrease separation times in HPLC, such as using shorter columns with smaller diameter packing. 5 This paper focuses on increasing the speed of a common industrial analysis performed by SFC-the separation of diesel fuels into hydrocarbon group-types (i.e., saturates, mono-, di-, tri-, and polyaromatics). Diesel and jet fuel environmental and performance properties have been associated with the group-type compositions of these fuels.…”
Section: Introductionmentioning
confidence: 99%
“…The first approach is to use shorter columns with smaller diameter packing. 5,[23][24][25][26][27] Shortening the column reduces the separation efficiency. Using a smaller diameter packing helps offset this by improving the plate height.…”
Section: Introductionmentioning
confidence: 99%