2022
DOI: 10.1039/d1ay02201f
|View full text |Cite
|
Sign up to set email alerts
|

Fast, sensitive and selective simultaneous determination of paraquat and glyphosate herbicides in water samples using a compact electrochemical sensor

Abstract: We report a new ready-to-use sensor for simultaneous determination of paraquat (PQ) and glyphosate (GLY) based on a graphite screen-printed electrode modified with a dual-molecularly imprinted polymer coated on a mesoporous silica-platinum core.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(8 citation statements)
references
References 50 publications
1
7
0
Order By: Relevance
“…This result confirms that GQDs-AuNPs@dual-MIP spheres are electrocatalytically active and highly affine to 4-NQO. This observation is in line with previous reports. ,, …”
Section: Methodssupporting
confidence: 94%
See 1 more Smart Citation
“…This result confirms that GQDs-AuNPs@dual-MIP spheres are electrocatalytically active and highly affine to 4-NQO. This observation is in line with previous reports. ,, …”
Section: Methodssupporting
confidence: 94%
“…This observation is in line with previous reports. 22,31,39 Optimization of Polymerization Conditions. As illustrated in Scheme 1, we encapsulated the GQDs-AuNPs core in SiO 2 via binding MPTMS via its thiol groups to the gold during the one-step shell-growth method.…”
Section: ■ Introductionmentioning
confidence: 99%
“…Under the optimal conditions, Pb 2+ incubation concentrations were progressively increased from 0 to 9 μM. Under the DPV detection, 34 we observed an oxidation peak of MB at −0.22 V, while a strong oxidation peak of Fc was observed near 0.2 V. Of course, the oxidation peaks of lead and oxygen can also be detected under DPV detection. Still, they were far from the target signal peak.…”
Section: Resultsmentioning
confidence: 60%
“…A dual-MIP was fabricated by 3D-printing on the surface of mesoporous SiPtNPs, using acrylic acid and N -vinyl-2-pyrrolidone as functional monomers, and N , N ′-(1,2-dihydroxyethylene) bis­(acrylamide) (DHEBA) as the cross-linking monomer. The sensors allowed for simultaneous determination of both herbicides, paraquat, and GLP, in water samples in the LDCR of 0.025–500 μM and with the LOD of 3.1 nM and 4 nM, respectively …”
Section: Sensors and Separation Systems For Glp Determinationmentioning
confidence: 99%
“…102 Furthermore, in a recent study, a gold chip/electrode coated with a self-assembled monolayer of GLP, in water samples in the LDCR of 0.025−500 μM and with the LOD of 3.1 nM and 4 nM, respectively. 144 A typical base-catalyzed sol−gel transition incorporation was performed to incorporate GLP and graphene QD labels into mesoporous organosilica MIPs. The GLP-induced quenchingmediated detection enabled GLP quantification at a subnanomolar level (0.017 ppb, 17 pg/mL).…”
Section: Electrochemical Sensors For Glpmentioning
confidence: 99%