2011
DOI: 10.1109/tpwrd.2011.2107530
|View full text |Cite
|
Sign up to set email alerts
|

Fast Protection of Strong Power Systems With Fault Current Limiters and PLL-Aided Fault Detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
3
1

Relationship

0
10

Authors

Journals

citations
Cited by 24 publications
(8 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…The Continuous Wavelet Transform (CWT) of a signal f (t), depends on two variables: scale (or frequency), designated by the parameter "a", and time (or position), designated by the parameter "b", and is given by: (4) being, the real function…”
Section: B Transform Waveletmentioning
confidence: 99%
“…The Continuous Wavelet Transform (CWT) of a signal f (t), depends on two variables: scale (or frequency), designated by the parameter "a", and time (or position), designated by the parameter "b", and is given by: (4) being, the real function…”
Section: B Transform Waveletmentioning
confidence: 99%
“…The advent of the phase-locked loop (PLL) dates back to 1930s when it was first designed and used for the synchronous reception of radio signals [1]. Since then, it has found widespread applications in different areas, such as the estimation of fundamental parameters (phase, frequency, and amplitude) of power signals [2]- [83], measurement of harmonics, interharmonics and power quality indices [84]- [90], implementing adaptive filters and robust controllers [91]- [93], control of AC and DC machines [94], [95], contactless energy transfer systems [96], [97], induction heating systems [98], [99], piezoelectric applications [100], [101], battery charge circuits [102], [103], magnetic encoders [104], islanding detection of microgrids [105]- [107], welding industry [108], grid fault and voltage sag detection [109], [110], synchronization of power quality instruments [111], [112], computation of synchrophasors [113], [114], etc. Fig.…”
Section: Introductionmentioning
confidence: 99%
“…Travelling wave distance protection cannot protect the whole line and does not have direction discrimination ability. Same with differential protection, it is affected by bus structure, too [6][7][8][9]. Travelling wave amplitude comparison protection principle has improved much compared to other protection principles.…”
Section: Introductionmentioning
confidence: 99%