The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2021
DOI: 10.1364/ol.421394
|View full text |Cite
|
Sign up to set email alerts
|

Fast Mueller matrix microscope based on dual DoFP polarimeters

Abstract: In this Letter, we report a dual division of focal plane (DoFP) polarimeters-based full Mueller matrix microscope (DoFPs-MMM) for fast polarization imaging. Both acquisition speed and measurement accuracy are improved compared with those of a Mueller matrix microscope based on dual rotating retarders. Then, the system is applied to probe the polarization properties of a red blood cells smear. The experimental results show that a DoFPs-MMM has the potential to be a powerful tool for probing dynamic processes in… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
34
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 67 publications
(38 citation statements)
references
References 17 publications
0
34
0
Order By: Relevance
“…The backscattering MMI system is based on DoFP which was successfully used in an upright transmission Mueller matrix microscope for fast MMI of tissue slides and cells [11]. In the system, as shown in Figure 1a, all cage system accessories were provided by RayCage(Zhenjiang) Photoelectric Technol-ogy Co., Ltd. Diffusing light from LED source (10 W, 633 nm, Cree) is collimated by a lens (L1, Daheng Optic, Beijing, China) and then modulated by the polarization states generator (PSG) which consists of a polarizer (P1, extinction ratio >1000:1, Daheng Optic, Beijing, China) and a quarter-wave plate (R1, LBTEK Optic, Changsha, China) fixed on a motorized rotation stage (PRM1/Z8, Thorlabs, Newton, NJ, USA).…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations
“…The backscattering MMI system is based on DoFP which was successfully used in an upright transmission Mueller matrix microscope for fast MMI of tissue slides and cells [11]. In the system, as shown in Figure 1a, all cage system accessories were provided by RayCage(Zhenjiang) Photoelectric Technol-ogy Co., Ltd. Diffusing light from LED source (10 W, 633 nm, Cree) is collimated by a lens (L1, Daheng Optic, Beijing, China) and then modulated by the polarization states generator (PSG) which consists of a polarizer (P1, extinction ratio >1000:1, Daheng Optic, Beijing, China) and a quarter-wave plate (R1, LBTEK Optic, Changsha, China) fixed on a motorized rotation stage (PRM1/Z8, Thorlabs, Newton, NJ, USA).…”
Section: Methodsmentioning
confidence: 99%
“…Polarization imaging can be achieved by adding a polarization states generator and analyzer to existing optical systems. For example, common optical microscopes can be upgraded for polarization imaging [11]. Compared with traditional non-polarized optical methods, a polarization measurement can provide much richer information on the microstructure of scattering samples such as biological tissues [12].…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…In the data acquisition procedure, we used two types of transmitted MM microscopes based on dual rotating retarders (DRR) [24] and dual division of focal plane polarimeters (DoFPs) [25]. DRR measures 30 images (polarimetric components) with specific incident and output polarization states by the rotation of two retarders.…”
Section: Data Acquisition and Preprocessing 21 | MM Acquisition Syste...mentioning
confidence: 99%