2022
DOI: 10.3390/ma15196807
|View full text |Cite
|
Sign up to set email alerts
|

Fast Isocenter Determination Using 3D Polymer Gel Dosimetry with Kilovoltage Cone-Beam CT Reading and the PolyGeVero-CT Software Package for Linac Quality Assurance in Radiotherapy

Abstract: This work presents an approach to the fast determination of a medical accelerator irradiation isocenter as a quality assurance (QA) procedure in radiotherapy. The isocenter determination tool is the tissue equivalent high-resolution 3D polymer gel dosimeter (PABIGnx) in a dedicated container combined with kilovoltage imaging systems and the polyGeVero-CT software package (v. 1.2, GeVero Co., Poland). Two accelerators were employed: Halcyon and TrueBeam (Varian, USA), both equipped with cone beam computed tomog… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
22
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 7 publications
(22 citation statements)
references
References 46 publications
0
22
0
Order By: Relevance
“…For this, De Deene (2010) provided detailed descriptions and recommendations on the MR-scanning procedure of polymer gels. As further examples, Elter et al (2021a) and Maras and Kozicki (2022) have provided detailed protocols for the PAGAT and PABIG nx dosimetry gels, respectively. In addition, several commercial (Kozicki et al 2014, Kozicki andMaras 2015), freely available (Elter et al 2021a) and open source-based (Alexander et al 2015) software packages for the evaluation of PG measurements have been developed and validated for different evaluation methods (Alexander et al 2015, Gharehaghaji and Dadgar 2018, Tajaldeen and Alghamdi 2019, Elter et al 2019b, Elter et al 2021b.…”
Section: Standardization Of Gel Dosimetry Workflowmentioning
confidence: 99%
See 2 more Smart Citations
“…For this, De Deene (2010) provided detailed descriptions and recommendations on the MR-scanning procedure of polymer gels. As further examples, Elter et al (2021a) and Maras and Kozicki (2022) have provided detailed protocols for the PAGAT and PABIG nx dosimetry gels, respectively. In addition, several commercial (Kozicki et al 2014, Kozicki andMaras 2015), freely available (Elter et al 2021a) and open source-based (Alexander et al 2015) software packages for the evaluation of PG measurements have been developed and validated for different evaluation methods (Alexander et al 2015, Gharehaghaji and Dadgar 2018, Tajaldeen and Alghamdi 2019, Elter et al 2019b, Elter et al 2021b.…”
Section: Standardization Of Gel Dosimetry Workflowmentioning
confidence: 99%
“…BAREX TM , VELOX GmbH, Hamburg, Germany), which have been shown to be compatible with the PG (Haraldsson et al 2000, Mann et al 2017b. As an alternative, PMMA may be used (Maras and Kozicki 2022), which can be easily processed. For PMMA, however, the container wall has to be thick enough to seal the PG against oxygen from the outside, and even if this is assured, small amounts of oxygen dissolved within the PMMA may still alter the PG response in regions close to the container wall.…”
Section: Challenges For Future Clinical Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…[ 1 ] Further research concerned both Fricke‐gel dosimeters and other systems, such as polymer gel dosimeters, radiochromic gel and plastic dosimeters, and flexible dosimeters. [ 2–59 ] Many dosimetric compositions have been proposed. As a general rule, each new 3D dosimeter has a specific acronym, usually derived from its components.…”
Section: Introductionmentioning
confidence: 99%
“…As a general rule, each new 3D dosimeter has a specific acronym, usually derived from its components. Examples of 3D polymer gel dosimeters are as follows (the acronyms are associated with example references): BANG, [16] PAG, [17] PAGAT, [18] nMAG, nPAG, [19] MAGIC, [17,20] MAGIC-f, [21] NIPAM, [22,23] VIPAR, [24] VIP (VIPAR nd ), [25] VIC, [26] VIC-T, [26] VIP3-Pluronic F-127, [27,28] PAGAT2-Pluronic F-127, [29] PAB-IG nx , [14,30,31] NHMAGAT, [32] MAGADIT, [33] NMPAGAT. [34] Examples of 3D radiochromic dosimeters are as follows: PVA-GTA-XO-Fricke, [35,36] PVA-GTA-MTB-Fricke, [37] Fricke-XOgelatine, [38] Fricke-XO-Pluronic F-127, [10,13,39] TTC-Pluronic F-127, [40] NBT-Pluronic F-127, [41,42] KI-PVA, [43] KI-Pluronic F-127, [12] LCV-gelatine; [44] and 3D plastic radiochromic dosimeter: PRESAGE.…”
mentioning
confidence: 99%