2023
DOI: 10.3390/bioengineering10060655
|View full text |Cite
|
Sign up to set email alerts
|

FAST (Flexible Acetylcholine Sensing Thread): Real-Time Detection of Acetylcholine with a Flexible Solid-Contact Potentiometric Sensor

Farbod Amirghasemi,
Ali Soleimani,
Shahd Bawarith
et al.

Abstract: Acetylcholine (ACh) is involved in memory and learning and has implications in neurodegenerative diseases; it is therefore important to study the dynamics of ACh in the brain. This work creates a flexible solid-contact potentiometric sensor for in vitro and in vivo recording of ACh in the brain and tissue homogenate. We fabricate this sensor using a 250 μm diameter cotton yarn coated with a flexible conductive ink and an ACh sensing membrane that contains a calix[4]arene ionophore. The exposed ion-to-electron … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 79 publications
0
3
0
Order By: Relevance
“…where K I is an experimentally determined constant potential value and a I is the primary ion activity. If interfering ions are introduced for ACh detection, the well-established Nikolsky-Eisenman equation would be more appropriate, 143 ( )…”
Section: Potentiometric Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…where K I is an experimentally determined constant potential value and a I is the primary ion activity. If interfering ions are introduced for ACh detection, the well-established Nikolsky-Eisenman equation would be more appropriate, 143 ( )…”
Section: Potentiometric Methodsmentioning
confidence: 99%
“…6 A. 145 Amirghasemi et al in 2023 143 developed a flexible solid-contact potentiometric sensor enriched with a calix [4]arene ionophore for ACh concentration detection in the brain. The sensor demonstrated impressive linearity and a low limit of detection (LOD) in HEPES buffer pH 4.0, although the LOD increased when tested in artificial cerebrospinal fluid due to background signals.…”
Section: Potentiometric Methodsmentioning
confidence: 99%
“…4 shows the main steps for preparing the TMA sensor, its morphological image, as well as photos of the portable sensing device. Carbon black has also been used as a solid contact in SC-ISEs for the determination of Na + , K + , NO 3 − , and acetylcholine, 103–108 exhibiting a Nernstian response with low LODs.…”
Section: Applications Of Nanomaterial-based Sc-isesmentioning
confidence: 99%