2013
DOI: 10.1016/j.atmosenv.2012.10.052
|View full text |Cite
|
Sign up to set email alerts
|

Fast determination of 3-ethenylpyridine as a marker of environmental tobacco smoke at trace level using direct atmospheric pressure chemical ionization tandem mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 32 publications
0
7
0
Order By: Relevance
“…The standard solution with the lowest concentration of the calibration curves was analyzed for 10 times, and then their standard deviation (SD) was calculated. LOD and LOQ were defined, respectively, as three times of SD and ten times of SD [ 28 ]. The LOD value obtained using this method described here was comparable to those reported by Medeiros [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…The standard solution with the lowest concentration of the calibration curves was analyzed for 10 times, and then their standard deviation (SD) was calculated. LOD and LOQ were defined, respectively, as three times of SD and ten times of SD [ 28 ]. The LOD value obtained using this method described here was comparable to those reported by Medeiros [ 29 ].…”
Section: Methodsmentioning
confidence: 99%
“…The original APCI probe assembly has been modified as described in the Ref. [21, 24]. The original capillary (0.15 mm i.d., 0.39 mm o.d.)…”
Section: Methodsmentioning
confidence: 99%
“…The volatile compounds in the vessel were swept along the nitrogen gas whose flow rate was controlled by a mass flow controller (MFC) and finally analyzed by improved CFI-MS. The sampling vessel was passivated according to the reported method [30]: the inner wall of the vessel was defatted with acetone and then dried for 2 h at 140 °C before usage; then the vessel was filled with a 5% (w/w) solution of dimethyldichlorosilane in toluene in order to deactivate the glass surface and the solution was removed after 24 h at room temperature; finally, the vessel was rinsed with toluene then methanol and dried in a stream of nitrogen [24].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The ionization of sample for APCI was carried out through ion-molecule reaction in gas phase, which was more suitable for the direct detection of gas sample. Recently, APCI-MS had been applied in direct monitoring of volatile organic compounds in ambient air [ 19 21 ].…”
Section: Introductionmentioning
confidence: 99%