2004
DOI: 10.1007/978-3-642-18536-6_2
|View full text |Cite
|
Sign up to set email alerts
|

Fast Detection and Processing of Arbitrary Contrast Agent Injections in Coronary Angiography and Fluoroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0

Year Published

2009
2009
2017
2017

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(25 citation statements)
references
References 6 publications
0
25
0
Order By: Relevance
“…4. In order to provide automatic roadmapping [2], the algorithm needs to know when the contrast agent appears in the fluoroscopy to disable the overlay. All these interventional procedures can be streamlined with a robust and automatic contrast inflow detection algorithm such that the physician can obtain desired information with less interactions or constraints.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…4. In order to provide automatic roadmapping [2], the algorithm needs to know when the contrast agent appears in the fluoroscopy to disable the overlay. All these interventional procedures can be streamlined with a robust and automatic contrast inflow detection algorithm such that the physician can obtain desired information with less interactions or constraints.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, this works poorly in practice since moving diaphragm and other darker regions can often appear in cardiac Xray images and mislead the algorithm. Condurache [2] et al proposed a method which applies morphological operations and a difference of Gaussians (DoG) filter to generate a vessel map. A threshold is then applied to the histogram of the vessel map to decide whether contrast medium appears.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Enhanced contrasted aortic root shows up dark pixels in the entire aorta roadmap if the contrast agent is injected. By analyzing the histogram and using the 98-percentile as a threshold measure of contrast agent, the enhanced contrast image is automatically detected after learning histogram feature curve of the first 20 images of sequence without contrast agent (Condurache et al, 2004). The aortic mesh model, valve landmarks and target area of implantation are projected to the fluoroscopic image plane using the transformation matrix of interventional C-arm imaging system.…”
Section: Contrast Image Detection and Aortic Mesh Model Alignmentmentioning
confidence: 99%
“…The proposed tracking algorithm automatically detects the images in which the aortic root and the coronary arteries are filled with contrast agent using histogram-based feature of the images [13]. The image sequence is frozen as soon as the contrast agent is detected in this image to provide the manual initialization of coronary ostia locations.…”
Section: ) Avp Trackingmentioning
confidence: 99%