2021
DOI: 10.1016/j.solener.2021.09.042
|View full text |Cite
|
Sign up to set email alerts
|

Fast calculation of latent heat storage process in the direct steam generation solar thermal power system using a POD reduced-order model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 37 publications
0
3
0
Order By: Relevance
“…The paper mainly focuses on the calculation of short-circuit current for the protection configuration of the high-voltage auxiliary power system in solar thermal power plants. The short-circuit current only calculates values related to protection, The scope of calculation includes short-circuit calculation of high-voltage auxiliary busbar (including maximum threephase short-circuit of high-voltage busbar, minimum two-phase short-circuit of high-voltage busbar, single-phase grounding short-circuit of high-voltage busbar) and short-circuit calculation of high-voltage auxiliary feeder (including short-circuit calculation of high-voltage auxiliary power supply feeder, low-voltage auxiliary transformer, and highvoltage auxiliary motor) [4][5][6] .…”
Section: Scope Of Fault Analysis and Calculationmentioning
confidence: 99%
“…The paper mainly focuses on the calculation of short-circuit current for the protection configuration of the high-voltage auxiliary power system in solar thermal power plants. The short-circuit current only calculates values related to protection, The scope of calculation includes short-circuit calculation of high-voltage auxiliary busbar (including maximum threephase short-circuit of high-voltage busbar, minimum two-phase short-circuit of high-voltage busbar, single-phase grounding short-circuit of high-voltage busbar) and short-circuit calculation of high-voltage auxiliary feeder (including short-circuit calculation of high-voltage auxiliary power supply feeder, low-voltage auxiliary transformer, and highvoltage auxiliary motor) [4][5][6] .…”
Section: Scope Of Fault Analysis and Calculationmentioning
confidence: 99%
“…This integration effectively addresses the uneven distribution of solar energy across both time and space, thereby mitigating day-night peak/valley differences. 2 Additionally, Furthermore, LHTES contributes to the repurposing of plant waste heat, thereby supporting initiatives for energy conservation and emission reduction.…”
Section: Introductionmentioning
confidence: 99%
“…Consequently, LHTES assumes a pivotal role as an indispensable component in direct steam generation (DSG) systems, commonly utilized in solar thermal power generation installations. This integration effectively addresses the uneven distribution of solar energy across both time and space, thereby mitigating day‐night peak/valley differences 2 . Additionally, Furthermore, LHTES contributes to the repurposing of plant waste heat, thereby supporting initiatives for energy conservation and emission reduction.…”
Section: Introductionmentioning
confidence: 99%