Fast and Slow Water Ion Populations in the Enceladus Plume

Abstract: Ion velocities have been measured during the Enceladus E3 and E5 flybys using the Cassini Plasma Spectrometer (CAPS) instrument on the Cassini spacecraft. Data from three sensors in the CAPS instrument have been examined from two flybys that occurred during 2008. Positive ion measurements from the CAPS Ion Beam Spectrometer and Ion Mass Spectrometer have been used to measure positive ion velocities. The CAPS Electron Spectrometer has been used to complement the positive ion findings with measurements of negati… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 47 publications
(109 reference statements)
0
2
0
Order By: Relevance
“…The instrument observed fluxes of negative ions in the Enceladus plumes during the Enceladus encounters in 2008 (Coates et al, 2010). The analysis of the observations revealed the abundance of water group negative ions (Haythornthwaite et al, 2020). In Figure 7, we show ELS observations during the Cassini's E3 flyby, in terms of logarithm of the count rates (C/Δτ), recorded in azimuth anode 5, as a function of energy and time.…”
Section: Application To Flight Datamentioning
confidence: 99%
See 1 more Smart Citation
“…The instrument observed fluxes of negative ions in the Enceladus plumes during the Enceladus encounters in 2008 (Coates et al, 2010). The analysis of the observations revealed the abundance of water group negative ions (Haythornthwaite et al, 2020). In Figure 7, we show ELS observations during the Cassini's E3 flyby, in terms of logarithm of the count rates (C/Δτ), recorded in azimuth anode 5, as a function of energy and time.…”
Section: Application To Flight Datamentioning
confidence: 99%
“…In another example, observations by the electron spectrometer of Cassini Plasma Spectrometer (CAPS/ELS, Young et al, 2004) allow the detection of heavy negative ions in the vicinity of Titan (e.g., Coates et al, 2007;Desai et al, 2017;Wellbrock et al, 2013;Wellbrock et al, 2019) and Enceladus plume (e.g., Coates et al, 2010;Haythornthwaite et al, 2020). In these cases, the heavy ion plasma is quasistatic and the bulk velocity of the ions in the spacecraft frame is the spacecraft ram speed, therefore, it is the same for all plasma species.…”
Section: Introductionmentioning
confidence: 99%