2015
DOI: 10.1039/c5ra05598a
|View full text |Cite
|
Sign up to set email alerts
|

Fast and selective determination of phenazopyridine at a novel multi-walled carbon nanotube modified ZnCrFeO4magnetic nanoparticle paste electrode

Abstract: Fabrication process of MWCNTs/ZnCrFeO4 modified carbon paste electrode for electrocatalytic determination of phenazopyridine at the surface (a) CPE, and (b) MWCNTs/ZnCrFeO4 modified carbon paste electrode.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
10
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 28 publications
1
10
0
Order By: Relevance
“…The reason for this may be due to the nanometer dimensions of MWCNTs, the electronic structure and the topological defects (edge plane-like sites/defects) present on MWCNTs surfaces. Meanwhile, the MWCNTs increase the effective area of the electrode [4].Therefore, they can incorporate into electrochemical sensors offering unique advantages including low detection limits, high sensitivities, reduction of over-potentials, and resistance to surface fouling [5,6].…”
Section: Accepted Manuscriptmentioning
confidence: 99%
See 3 more Smart Citations
“…The reason for this may be due to the nanometer dimensions of MWCNTs, the electronic structure and the topological defects (edge plane-like sites/defects) present on MWCNTs surfaces. Meanwhile, the MWCNTs increase the effective area of the electrode [4].Therefore, they can incorporate into electrochemical sensors offering unique advantages including low detection limits, high sensitivities, reduction of over-potentials, and resistance to surface fouling [5,6].…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…of K 3 Fe(CN) 6 and ν is the scan rate. For 1mmol L -1 K 3 Fe(CN) 6 in the 0.1mol L -1 KCl electrolyte: n = 1 and D R =7.6×10 −6 cm 2 s −1 , then from the slope of the I pa -ν 1/2 relation, the real surface area was calculated.…”
Section: Morphological Characterization Of Mnfe 2 O 4 Nanoparticlesmentioning
confidence: 99%
See 2 more Smart Citations
“…Nanomaterials have severed as promising candidates for modifiers and are commonly used in the construction of potentiometric sensors. As reported in the literatures, the linear range and detection limits of potentiometric sensors modified with nanomaterials have been improved by several orders of magnitudes compared to their unmodified counterparts [ 15 17 ]. Hematite (α-Fe 2 O 3 ) is one of the most promising nanomaterials with high electric conductivity, large surface area, and good photocatalytic activity [ 18 20 ], which has received considerable attention due to its versatile applications in fabricating gas sensors [ 21 , 22 ].…”
Section: Introductionmentioning