2020
DOI: 10.1007/s10661-020-8065-0
|View full text |Cite
|
Sign up to set email alerts
|

Fast and effective simultaneous determination of metals in soil samples by ultrasound-assisted extraction and flame atomic absorption spectrometry: assessment of trace elements contamination in agricultural and native forest soils from Paraná - Brazil

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
5
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 37 publications
0
5
0
Order By: Relevance
“…Following scientific literature reports [ 18 , 19 , 26 ], the ultrasound-assisted BCR sequential extraction method based on the use of ultrasound waves for heavy metal extraction allows similar results in comparison with the conventional BCR extraction method to be obtained. However, the extraction efficiency of heavy metals from solid samples like sewage sludge depends on several factors and technical parameters of the process, i.e., the type of ultrasound processor, the frequency and intensity characteristics of the wave, the sonication time, and the temperature [ 25 , 26 , 31 ]. Therefore, the optimization of different factors that have an impact on the process of ultrasound-assisted BCR sequential extraction is important in order to obtain results which are comparable to those achieved by the conventional method.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Following scientific literature reports [ 18 , 19 , 26 ], the ultrasound-assisted BCR sequential extraction method based on the use of ultrasound waves for heavy metal extraction allows similar results in comparison with the conventional BCR extraction method to be obtained. However, the extraction efficiency of heavy metals from solid samples like sewage sludge depends on several factors and technical parameters of the process, i.e., the type of ultrasound processor, the frequency and intensity characteristics of the wave, the sonication time, and the temperature [ 25 , 26 , 31 ]. Therefore, the optimization of different factors that have an impact on the process of ultrasound-assisted BCR sequential extraction is important in order to obtain results which are comparable to those achieved by the conventional method.…”
Section: Resultsmentioning
confidence: 99%
“…However, taking into account the number of scientific papers referencing the use of ultrasound waves in the process of the sequential extraction of heavy metals from soils or sediments [ 19 , 23 , 31 , 32 , 33 , 34 , 35 , 36 ], there are still only a few studies that concern sewage sludge [ 5 , 18 , 24 , 25 , 26 ]. Therefore, we decided to undertake research in this direction.…”
Section: Resultsmentioning
confidence: 99%
“…The analysis of the concentrations of elements in samples was performed by FAAS [ 16 , 71 ] using a ContrAA ® 700 spectrometer, with a high-resolution double-scale monochromator optical system, its spectral resolution in the interval 0.002–200 nm, and the wavelength between 185 and 900 nm [ 6 , 7 ]. A quantity of 0.5 g of powder of the plants’ dry flowers was mineralized with 5 mL nitric acid and 40 mL deionized water to 120 °C for 130 min.…”
Section: Methodsmentioning
confidence: 99%
“…The concentrations of macroelements (Ca, Na, K, and Mg), trace elements (Cu, Zn, Mn, Fe, and Cd), and microelements in the samples was performed via FAAS [ 35 , 36 , 37 ], using a ContrAA ® 700 spectrometer whose main characteristics are presented in Table 1 .…”
Section: Methodsmentioning
confidence: 99%