1987
DOI: 10.1364/ao.26.003818
|View full text |Cite
|
Sign up to set email alerts
|

Far-infrared high-resolution Fourier transform spectrometer

Abstract: Design and performance of a high-resolution Fourier transform spectrometer for laboratory molecular spectroscopy in the 8-200-cm(-1) region are discussed. A folding of the beam path is used to obtain the maximum path difference of 4 m with a mirror stroke of 1 m. The measured linewidth of 0.0019 cm(-1) is in agreement with the expected theoretical resolution.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

1988
1988
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…In thefirst case about k330MHz can be explored thanks to the 120 MHz tunability of the waveguide CO2 laser and to the use of 90 MHz opto-acoustic modulators which are used to isolate the output beams of the CO2 beams from the MIM diode. In the second case the tunability comes from the microwave source (2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20) used to add the tunable sidebands to the CO, difference frequency.…”
Section: Coherent Atomic and Molecular Spectroscopjr In The Farmentioning
confidence: 99%
See 2 more Smart Citations
“…In thefirst case about k330MHz can be explored thanks to the 120 MHz tunability of the waveguide CO2 laser and to the use of 90 MHz opto-acoustic modulators which are used to isolate the output beams of the CO2 beams from the MIM diode. In the second case the tunability comes from the microwave source (2)(3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13)(14)(15)(16)(17)(18)(19)(20) used to add the tunable sidebands to the CO, difference frequency.…”
Section: Coherent Atomic and Molecular Spectroscopjr In The Farmentioning
confidence: 99%
“…As a consequence a total 10 GHz wide scan, corresponding to the Phyuca Scripta 37 Fig. 15. Comparison between the 3rd order Tunable far Infrared spectrometer (a) and the best available [8] FTS recording (b). By means of the new coherent technique the regions A--t B-and A + + B+ (each of them 5 GHz wide) can now be investigated with aresolution of about 50 KHz.…”
Section: Spectroscopical Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…As the number of optical path folds increases, the requirements for the collimation of the beam become higher. These problems Factors will affect the interference intensity [13][14][15] . At the same time, only a few methods are suitable for spectral imaging.…”
Section: Introductionmentioning
confidence: 99%