2018
DOI: 10.1049/iet-pel.2017.0758
|View full text |Cite
|
Sign up to set email alerts
|

Family of isolated bidirectional resonant converters with duty‐cycle control and automatic power flow transition

Abstract: This study proposes a family of duty-cycle controlled bidirectional resonant converters and its uniform modulation schemes. This family of converters is composed of a current-fed stage, a transformer with LC resonant tank and a voltage-fed stage. Therefore, high-voltage gain and low-current ripple can be achieved. With the proposed uniform modulation schemes, automatic forward and backward mode transition is realised. Furthermore, the voltage gain is only determined by the duty cycle, independent of load and p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 27 publications
(55 reference statements)
0
2
0
Order By: Relevance
“…In modern days, uninterruptible power supply (UPS) systems are usually used at the utility grid as the main power source and the batteries are used as a backup power source [12,13]. Thus, for systems interfacing the ESS with the DC bus, the bidirectional DC-DC converters with power flow control have been widely discussed for effective power conversion [14][15][16][17][18][19][20][21]. Several research groups have discussed the possible methods of improving the quality of the power flow by modifying the circuit topology [14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In modern days, uninterruptible power supply (UPS) systems are usually used at the utility grid as the main power source and the batteries are used as a backup power source [12,13]. Thus, for systems interfacing the ESS with the DC bus, the bidirectional DC-DC converters with power flow control have been widely discussed for effective power conversion [14][15][16][17][18][19][20][21]. Several research groups have discussed the possible methods of improving the quality of the power flow by modifying the circuit topology [14][15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…Thus, for systems interfacing the ESS with the DC bus, the bidirectional DC-DC converters with power flow control have been widely discussed for effective power conversion [14][15][16][17][18][19][20][21]. Several research groups have discussed the possible methods of improving the quality of the power flow by modifying the circuit topology [14][15][16][17]. Vuyyuru et al and Khan et al have also illustrated different control strategies for improving the power flow quality [18][19][20].…”
Section: Introductionmentioning
confidence: 99%