2021
DOI: 10.14366/usg.19076
|View full text |Cite
|
Sign up to set email alerts
|

False-negative results on computer-aided detection software in preoperative automated breast ultrasonography of breast cancer patients

Abstract: Epub ahead of printPurpose: The purpose of this study was to measure the cancer detection rate of computer-aided detection (CAD) software in preoperative automated breast ultrasonography (ABUS) of breast cancer patients and to determine the characteristics associated with false-negative outcomes. Methods: A total of 129 index lesions (median size, 1.7 cm; interquartile range, 1.2 to 2.4 cm) from 129 consecutive patients (mean age±standard deviation, 53.4±11.8 years) who underwent preoperative ABUS from Decembe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 31 publications
0
3
0
Order By: Relevance
“…Peri-areolar shadowing is defined as a nipple artifact [30]. Despite the promising detection rate with CAD software in breast cancer, radiologists should determine whether a CAD software-marked lesion is a true-or false-positive lesion, given its positive predictive value and high false-positive rate [17]. The knowledge of these artifacts improves the diagnostic performance of radiologists.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Peri-areolar shadowing is defined as a nipple artifact [30]. Despite the promising detection rate with CAD software in breast cancer, radiologists should determine whether a CAD software-marked lesion is a true-or false-positive lesion, given its positive predictive value and high false-positive rate [17]. The knowledge of these artifacts improves the diagnostic performance of radiologists.…”
Section: Discussionmentioning
confidence: 99%
“…According to the manual from the manufacturer, FPR was defined as the total number of false-positive CAD markers in non-cancer volumes divided by the total number of non-cancer volumes. In this study, we set the FPR to 0.2 (i.e., 1 false-positive CAD marker in non-cancer volume per 5 non-cancer volumes), which was its default setting as in previous studies [16][17][18].…”
Section: Cad Systemmentioning
confidence: 99%
“…Due to the considerable amount of ABUS images, reviewing a full ABUS examination can be burdensome and malignant lesions may be overlooked. CAD software has been introduced to assist radiologists in interpretating images and generating accurate diagnosis [ 78 , 79 , 80 , 81 ], which would be a promising solution in LMICs with a lack of healthcare staff. A study in China evaluated the role of CAD in decreasing ABUS reading times and increasing the diagnostic accuracy of junior radiologists [ 82 ].…”
Section: Novel Techniques In Us For Bc Screeningmentioning
confidence: 99%