2021
DOI: 10.47196/diab.v55i2.473
|View full text |Cite
|
Sign up to set email alerts
|

Falla autonómica asociada a hipoglucemia

Abstract: La hipoglucemia inadvertida (HI) es una complicación del tratamiento de la diabetes mellitus tipo 1 (DM1) y DM2 tratada con insulina o sulfonilureas, que se caracteriza por una capacidad reducida para percibir el inicio de los episodios de hipoglucemia. En general, coexiste con una insuficiente respuesta hormonal contrarreguladora a la hipoglucemia denominada falla autonómica asociada a la hipoglucemia (FAAH). El desarrollo de HI y de falla contrarreguladora a la hipoglucemia aumentan significativamente el rie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 78 publications
0
3
0
Order By: Relevance
“…The body mass index (BMI) was ). Of the total population, 41 (55%) were female, and most had a diagnosis of T1D (71; 95%), with 20 years since diagnosis (IQR [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33]. The median number of years of follow-up using the SAP was four years (IQR 2-7).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The body mass index (BMI) was ). Of the total population, 41 (55%) were female, and most had a diagnosis of T1D (71; 95%), with 20 years since diagnosis (IQR [14][15][16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33]. The median number of years of follow-up using the SAP was four years (IQR 2-7).…”
Section: Resultsmentioning
confidence: 99%
“…The assessment of adherence to treatment and the measurement of variables related to insulin pump use were reviewed through the Care-Link Medtronic system software. We used the Gold scale as an assessment tool for hypoglycemia, with lower values indicating a greater perception of hypoglycemia and higher values re ecting a total loss of its perception [30].…”
Section: Methodsmentioning
confidence: 99%
“…Adherence to treatment and the measurement of variables related to insulin pump use were reviewed using the CareLink Medtronic system software. We used the Gold scale as an assessment tool for hypoglycemia awareness, with lower values indicating a greater perception of hypoglycemia and higher values reflecting a lack of perception [ 32 ].…”
Section: Methodsmentioning
confidence: 99%