2008
DOI: 10.1007/s11701-008-0080-z
|View full text |Cite
|
Sign up to set email alerts
|

Failure of a robotic arm during da Vinci prostatectomy: a case report

Abstract: We report a rare case of a da Vinci robotic arm failure during a laparoscopic robot-assisted radical prostatectomy. The articulation joint of an Endowrist needle driver was broken and positioned at such an angle that made it impossible to remove through the trocar. In addition, it was later discovered that a small piece of the instrument was detached and remained inside the abdomen of the patient without even having been identified on subsequent radiological evaluation. In order to remove the broken instrument… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0
1

Year Published

2010
2010
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 1 publication
(1 reference statement)
0
5
0
1
Order By: Relevance
“…Questions have thus been raised on its stability and reliability, however, there have been reports of minimal error and failure rates 1-3. This report aims to show that more attention should be given not only to the mechanical parts but also to its accessories as well.…”
Section: Introductionmentioning
confidence: 93%
See 1 more Smart Citation
“…Questions have thus been raised on its stability and reliability, however, there have been reports of minimal error and failure rates 1-3. This report aims to show that more attention should be given not only to the mechanical parts but also to its accessories as well.…”
Section: Introductionmentioning
confidence: 93%
“…Questions have thus been raised on its stability and reliability, however, there have been reports of minimal error and failure rates. 1 - 3 This report aims to show that more attention should be given not only to the mechanical parts but also to its accessories as well. Extra caution should be exercised in the maintenance and care of the equipment to eliminate unnecessary complications during and after the operative procedure.…”
Section: Introductionmentioning
confidence: 99%
“…In the literature, every now and again single case reports are published that describe breaking of an instrument arm during robot-assisted intervention 82 . Those publications make clear that the application of robots bears new risks for the patients that have to be discussed during preoperative information.…”
Section: Risksmentioning
confidence: 99%
“…In der Literatur erscheinen immer wieder einzelne Fallberichte, in denen der Bruch eines Instrumentenarms während eines Roboter-assistierten Eingriffs beschrieben wird 82 . Diese Publikationen verdeutlichen, dass der Einsatz von Robotern neue Risiken für den Patienten birgt, welche in dem präoperativen Aufklärungsgespräch diskutiert werden müssen.…”
Section: Risikenunclassified
“…For example N. oliakos et al [5] report a rare case of a da Vinci robotic arm failure during a laparoscopic robot-assisted radical prostatectomy. The articulation joint of an Endowrist needle driver was broken and positioned at such an angle that made it impossible to remove through the trocar.…”
Section: Robin Heart Progress -Advances Materials and Technology In Sumentioning
confidence: 99%