2013
DOI: 10.1016/j.chroma.2013.06.050
|View full text |Cite
|
Sign up to set email alerts
|

Factors influencing the separation of oligonucleotides using reversed-phase/ion-exchange mixed-mode high performance liquid chromatography columns

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
32
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 69 publications
(34 citation statements)
references
References 19 publications
2
32
0
Order By: Relevance
“…Retention discrepancy was observed for all the groups with same base composition but different base sequence, indicating retention of oligonucleotide is also related to the base sequence. Same phenomenon was observed in the work of Biba et al [47], in which six base-flip isomeric RNAs showed a modest separation under a same IP-RP-HPLC condition due to the subtle difference in conformation. Additionally, in our work, for oligonucleotides with same base composition, there was a longer retention when two "T" were both near the 5'-end (oligos 5 and 6) than one "T" was exchanged by "G" (oligo 4).…”
Section: Retention Behavior Of Oligonucleotidessupporting
confidence: 78%
“…Retention discrepancy was observed for all the groups with same base composition but different base sequence, indicating retention of oligonucleotide is also related to the base sequence. Same phenomenon was observed in the work of Biba et al [47], in which six base-flip isomeric RNAs showed a modest separation under a same IP-RP-HPLC condition due to the subtle difference in conformation. Additionally, in our work, for oligonucleotides with same base composition, there was a longer retention when two "T" were both near the 5'-end (oligos 5 and 6) than one "T" was exchanged by "G" (oligo 4).…”
Section: Retention Behavior Of Oligonucleotidessupporting
confidence: 78%
“…Some researchers focused on the retention mechanism of the analytes on MMC columns . In addition, there are also a number of reports about the application of MMC stationary phases in the analysis of complex bio samples and natural products . Therefore, the MMC materials are of great potentials for the separation of complex samples.…”
Section: Introductionmentioning
confidence: 99%
“…A rare but noteworthy are attempts to determine the suitability of mixed-mode columns. An example is work of Biba et al [ 23 ] who evaluated several commercial columns consisting of ion-exchange and octadecyl ligands for RNA oligonucleotide analysis. The structural and positional isomers of studied biomolecules were separated due to the properties of these stationary phases, when typical anion-exchange mobile phases were used [ 23 ].…”
Section: Introductionmentioning
confidence: 99%