Abstract: Several factors contribute to the variability observed among repeated measurements of breath alcohol concentration. Identifying these factors and the magnitude of their contribution is the focus of this study. Large breath alcohol data sets consisting of duplicate test results from drivers arrested for driving while intoxicated were obtained from four jurisdictions: Sweden, Alabama, New Jersey and Washington State. The absolute difference between duplicate results were fitted to a multivariate linear regressio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
3
2
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…Variability exists in replicate breath alcohol exhalation profiles for one subject collected over a short time interval. There were no age or gender influences, while the breath exhalation volume and breath exhalation time also lacked significant associations [ 63 ]. However, the breathing pattern seems to have an effect.…”
Section: Breath Testmentioning
confidence: 99%
“…Variability exists in replicate breath alcohol exhalation profiles for one subject collected over a short time interval. There were no age or gender influences, while the breath exhalation volume and breath exhalation time also lacked significant associations [ 63 ]. However, the breathing pattern seems to have an effect.…”
Section: Breath Testmentioning
confidence: 99%
“…The quality assurance is important in conjunction with evidential breath alcohol testing considering that the results are used in a criminal prosecution as reviewed in detail elsewhere . For example, a suspect should be kept under observation for at least 15–20 min before a breath test to avoid claims that “mouth-alcohol” influenced the results. , Two separate exhalations should be analyzed from each suspect about 3–5 min apart, and a good agreement between the duplicate measurements represents an independent confirmatory test result. Accuracy of the breath-alcohol instrument is verified each time a suspect is tested by the analysis of known strength air-alcohol vapor standards generated using a wet-bath simulator or via compressed dry-gas standards traceable to some primary source. , …”
Section: Uncertainty Of Measurementmentioning
confidence: 99%
“…For in vivo use, manufacturers of these devices should consider programing the instrument for a duplicate breath test sequence, reporting the mean of the two measurements along with the associated uncertainty. An uncertainty function could be built into the software of the smartphone app to provide users with additional information about the uncertainty of the measurements obtained (48). Also, calibration reports could be recorded by the smartphone app and notify the user when recalibration is needed.…”
Section: Analytical Performancementioning
confidence: 99%