2010
DOI: 10.1038/eye.2010.179
|View full text |Cite
|
Sign up to set email alerts
|

Factors associated with topographic changes of the optic nerve head induced by acute intraocular pressure reduction in glaucoma patients

Abstract: Purpose To investigate factors associated with changes in optic nerve head (ONH) topography after acute intraocular pressure (IOP) reduction in patients with primary open-angle glaucoma (POAG). Methods Untreated POAG patients (IOP 421 mm Hg) were prospectively enrolled. Systemic and ocular information were collected, including central corneal thickness (CCT) and corneal hysteresis (CH). All patients underwent confocal scanning laser ophthalmoscopy and tonometry (Goldmann) before and 1 h after pharmacological I… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
26
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 29 publications
(26 citation statements)
references
References 58 publications
(77 reference statements)
0
26
0
Order By: Relevance
“…They suggested that the reduced viscous damping of the cornea, as represented by a low CH, reflects an increased likelihood of deformability of the ONH complex. 19 The present study on PACG eyes found no association between disease severity and either CH or CRF. Our study comprised exclusively of subjects with established glaucoma unlike the previous published studies that have included a wider range of subjects encompassing glaucoma suspects and established glaucoma.…”
Section: Discussionmentioning
confidence: 50%
See 1 more Smart Citation
“…They suggested that the reduced viscous damping of the cornea, as represented by a low CH, reflects an increased likelihood of deformability of the ONH complex. 19 The present study on PACG eyes found no association between disease severity and either CH or CRF. Our study comprised exclusively of subjects with established glaucoma unlike the previous published studies that have included a wider range of subjects encompassing glaucoma suspects and established glaucoma.…”
Section: Discussionmentioning
confidence: 50%
“…Although Vu et al 18 showed similar weak associations (r ¼ À0.11 to À0.15) of VCDR with CH, they did not report on the association with CRF. Likewise, Prata et al 19 demonstrated significant correlations with mean cup depth (r ¼ À0.34) and linear cup-disc ratio (r ¼ À0.41) in their evaluation of 42 newly diagnosed POAG patients. They suggested that the reduced viscous damping of the cornea, as represented by a low CH, reflects an increased likelihood of deformability of the ONH complex.…”
Section: Discussionmentioning
confidence: 99%
“…21,22 Furthermore, anterior displacement of prelaminar tissue following trabeculectomy for OAG has been described in a number of studies with variable results. Patients in these studies were followed up for periods varying from several weeks to 2 years, [1][2][3][4][5] and different patient populations and imaging platforms were used. Results from our study confirm topographic changes in adult ONHs following trabeculectomy, with significant anterior displacement of prelaminar tissue 1 week and 1 month after surgery.…”
Section: Discussionmentioning
confidence: 99%
“…A partial reversal of optic disc cupping and an improvement in neuroretinal rim appearance is observed in children after trabeculectomy, but is less commonly seen in adults. [1][2][3][4][5] Biomechanical factors that affect the optic nerve head (ONH) may strongly influence the glaucomatous process because the posterior sclera and lamina cribrosa (LC) are implicated in the pathophysiology of glaucomatous optic neuropathy. 6,7 Stereoscopic optic disc photography and scanning laser tomography have been widely used to study optic disc cupping reversal in adults after IOP reduction.…”
Section: Introductionmentioning
confidence: 99%
“…5 Keratoconus, Fuchs' dystrophy, Glaucoma, Marfan syndrome, and post-LASIK patients have been found to have low CH and CRF. [6][7][8][9][10][11][12][13] The corneal visualization Scheimpflug technology tonometer (Corvis ST tonometry: CST; Oculus, Wetzlar, Germany) was introduced more recently and allows quantitative and visual assessment of the biomechanical properties of the cornea. 14 The Corvis ST is a noncontact tonometer with an integrated ultra-high-speed Scheimpflug camera, enabling the direct visualization of corneal movement during the application of a rapid air-puff.…”
Section: Clinical Evaluation Of the Biomechanical Changes Occurring Imentioning
confidence: 99%