1981
DOI: 10.1097/00003246-198104000-00002
|View full text |Cite
|
Sign up to set email alerts
|

Factors affecting heated transcutaneous Po2 and unheated transcutaneous Po2 in preterm infants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
4
0

Year Published

1991
1991
2014
2014

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 21 publications
(5 citation statements)
references
References 0 publications
1
4
0
Order By: Relevance
“…In our normal healthy infants, comparison with arterial values was not warranted. Such a study was, however, performed previously and had yielded a correlation coeficient comparable to those obtained by others (18,23,25 In preterm and term infants during the first week of life, Hanson and Okken (6) reported a higher level of Ptco2 in QS than in AS. In our study, where the infants were at least 4 wk old, differences of Ptco2 during various states were restricted to variability and were not seen in levels.…”
Section: Discussionsupporting
confidence: 77%
“…In our normal healthy infants, comparison with arterial values was not warranted. Such a study was, however, performed previously and had yielded a correlation coeficient comparable to those obtained by others (18,23,25 In preterm and term infants during the first week of life, Hanson and Okken (6) reported a higher level of Ptco2 in QS than in AS. In our study, where the infants were at least 4 wk old, differences of Ptco2 during various states were restricted to variability and were not seen in levels.…”
Section: Discussionsupporting
confidence: 77%
“…Studies have shown that tissue perfusion and acidosis may alter such agreement. 17,18 Although we were not able to find differences in the correlation based on blood pressure, the sample size to assess the impact was probably inadequate. It is also possible that the technology, as currently available, is not yet ready to replace the gold standard.…”
Section: Resultsmentioning
confidence: 79%
“…Oxygen measured transcutaneously has typically been less closely associated with arterial levels than is the case for carbon dioxide. In neonates, correlation coefficients ranging from 0.72 to 0.98 have been reported 2 ,8,II,14, [16][17][18][19]. The mean differences between T0 2 and p0 2 in infants have been reported as 3 mmHg'6 while the bias and precision has been reported as 2.8±16.0 mmHg", 12.5±13.0 mmHg'S and 16.4±24.7 mmHg at p0 2 greater than 80 mmHg and 3.0±1O.2 mmHg at lower P022.…”
Section: Discussionmentioning
confidence: 98%