1997
DOI: 10.1016/s0584-8547(96)01587-x
|View full text |Cite
|
Sign up to set email alerts
|

Factorial optimization of data acquisition factors for lead isotope ratio determination by inductively coupled plasma mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
24
0
1

Year Published

2000
2000
2018
2018

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(26 citation statements)
references
References 27 publications
1
24
0
1
Order By: Relevance
“…This results in poor peak shape and consequently in less precise measurements than using multi-collector sector instruments [4]. Typically, precisions of around 0.1-1.0% are achieved [5,6], depending on the concentration or matrix and the 204 Pb isotope is seldom measured. However, isotopic ratios including the 204 Pb isotope are of crucial importance for source assessments.…”
Section: Introductionmentioning
confidence: 99%
“…This results in poor peak shape and consequently in less precise measurements than using multi-collector sector instruments [4]. Typically, precisions of around 0.1-1.0% are achieved [5,6], depending on the concentration or matrix and the 204 Pb isotope is seldom measured. However, isotopic ratios including the 204 Pb isotope are of crucial importance for source assessments.…”
Section: Introductionmentioning
confidence: 99%
“…The limits of detection for Pb and Cd were 0.005 and 0.002 lg L -1 in the present study. Lead isotopic analyses were conducted using a Perkin-Elmer ICP-MS SCIEX Elan 9000 as already described in the literature (Quétel et al 1997;Bindler et al 2004;Godoy et al 2007). Precision and accuracy were verified using a standard reference material from the National Institute of Standards and Technology (SRM 981 common lead isotopic material).…”
Section: Methodsmentioning
confidence: 99%
“…Many groups have tried to characterise and improve the precision of isotope ratio determination with ICP‐QMS . For example, Monna et al described the optimum integration times of measured isotopes depending on their isotopic composition for lead (Pb) and strontium (Sr).…”
Section: Introductionmentioning
confidence: 99%
“…Many groups have tried to characterise and improve the precision of isotope ratio determination with ICP-QMS. [12][13][14][15][16][17][18] For example, Monna et al 12 described the optimum integration times of measured isotopes depending on their isotopic composition for lead (Pb) and strontium (Sr). Some approaches are based on changes in hardware such as that by Gray et al 13 (using a free expansion interface and a bonnet to shield the ICP from the surrounding atmosphere) or the development of new devices for special applications such as multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS).…”
Section: Introductionmentioning
confidence: 99%