2018
DOI: 10.1049/iet-gtd.2017.1531
|View full text |Cite
|
Sign up to set email alerts
|

Factorial analysis for ageing assessment of in‐service transformers

Abstract: Condition monitoring data in the form of oil test results are important for transformer ageing assessment and asset management. In this paper, Analysis of Variance (ANOVA) based factorial analysis was demonstrated as a data mining technique for identifying the influence of different factors on transformer ageing. Using a UK oil test database of 33/11(or 6.6) kV transformers, studies were performed to assess the influence of in-service age, manufacturer, year of manufacture, load and environment on the measured… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 15 publications
(26 reference statements)
0
3
0
1
Order By: Relevance
“…Since only the substation systems are involved, the 102 buses network can be simplified as a radial system. Considering a potential impact of too many tap switching operations on OLTCs [31], the limited tap changer switching operation numbers TClimit has been set to 4 (i.e. M 4).…”
Section: Stimulation Results and Comparisonsmentioning
confidence: 99%
See 1 more Smart Citation
“…Since only the substation systems are involved, the 102 buses network can be simplified as a radial system. Considering a potential impact of too many tap switching operations on OLTCs [31], the limited tap changer switching operation numbers TClimit has been set to 4 (i.e. M 4).…”
Section: Stimulation Results and Comparisonsmentioning
confidence: 99%
“…This paper presents an improved optimal load demand reduction control strategy for the operation of primary transformer tap-changers in distribution networks, provided that the upstream transmission system requires active load demand reduction services during periods of low generation production or generation loss. Since frequent operation of OLTCs would impact the asset health of OLTC [31], the objective is thus to find an optimal dispatch solution of transformer OLTCs to achieve the required load demand reduction service by minimizing OLTC tap switching operations and the network power losses. Similar to the optimization method used in [32], but this paper optimizes transformer tap changers switching operations and network active power loss to provide load demand reduction supports to the upstream transmission network.…”
Section: Introductionmentioning
confidence: 99%
“…This approach presents higher accuracy in fault diagnosis Shrivastava & Choubey (2012). In 2018, the factor analysis based on ANOVA is exploited to evaluate the aging of transformers in service Wang et al (2018). Reference Ardi et al (2019) for diagnosing incipient faults in power transformers, uses analytical incremental learning (AIL) based on dissolved gas analysis.…”
Section: Some Applications Of Extraction Techniquesmentioning
confidence: 99%
“…El análisis factorial es una herramienta sumamente útil, puede ayudar a los administradores de activos a analizar grandes bases de datos, validar constructos y comprender más sobre los factores subyacentes que influyen en las variables y así planificar posteriormente la gestión de estrategias (Wang, Ji, Liu y Wang 2018;Hernández-Sampieri, Fernández, Baptista, 2010;Montgomery y Runger, 2010). Mediante esta técnica se encuentran grupos de variables homogéneas a partir de un conjunto numeroso de ellas (Pérez y Medrano, 2010).…”
Section: Microempresas Comercializadorasunclassified