2020
DOI: 10.1016/j.carbon.2020.05.060
|View full text |Cite
|
Sign up to set email alerts
|

Facile synthesis of pH-responsive gadolinium(III)-doped carbon nanodots with red fluorescence and magnetic resonance properties for dual-readout logic gate operations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
24
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 37 publications
(28 citation statements)
references
References 77 publications
3
24
0
1
Order By: Relevance
“…Additionally, based on the Gd 3+ -doped CD, they also developed an FL/MR dual-readout logic gates, wherein H + , OH − , Cu 2+ acted as input as they stimulate the fluorescence and MR response in a switched manner. Based on this phenomenon, the Gd 3+ -doped CD was employed in bioimaging [ 164 ]. Table 4 lists some of the other reported CDs with dual-functionality.…”
Section: Cds In Optical-based Analyticalmentioning
confidence: 99%
“…Additionally, based on the Gd 3+ -doped CD, they also developed an FL/MR dual-readout logic gates, wherein H + , OH − , Cu 2+ acted as input as they stimulate the fluorescence and MR response in a switched manner. Based on this phenomenon, the Gd 3+ -doped CD was employed in bioimaging [ 164 ]. Table 4 lists some of the other reported CDs with dual-functionality.…”
Section: Cds In Optical-based Analyticalmentioning
confidence: 99%
“…Other researchers developed IMPLICATION logic operations using the sensing ability of CDs for Hg (II) and cysteine [ 45 ], AA [ 46 ], Fe 3+ [ 47 ], Hg 2+ , and biothiols [ 48 ], Hg(II), and glutathione [ 49 ]. A multilevel single-output logic system was also developed using gadolinium doped CDs with H + , OH − , Cu 2+ as inputs, which trigger both Fluorescence intensity (FI) and magnetic resonance (MR) signals [ 50 ]. Apart from the fluorescence technique, using magnetic resonance signal for dual readout logic operations is of significant importance, as the combination of FL/MR techniques gives the logic devices better applicability in case of biological application.…”
Section: Logic Outputmentioning
confidence: 99%
“…De Silva et al were among the first to describe logic operations by means of molecules, and used fluorescence to do so [66]. Others continued similar work to have combinations of ions or other biologically relevant molecules affect the FI [25,32,43,60,62,[67][68][69][70][71][72][73][74][75][76][77], sometimes in very versatile settings to allow for easy manipulation of the system to create any desired logic gate [31,78]. Another direction has been the use of enzymes to affect the FI in logic operations [33,79].…”
Section: Logic Gates Using Fimentioning
confidence: 99%
“…Both Remón et al and Bai et al claimed to have measured FLT, but made no mention of the values [69, 81]. Fang et al measured the FLT for CD characterization, but not after introduction of analytes [77].…”
Section: Different Kinds Of Logic Gatesmentioning
confidence: 99%
See 1 more Smart Citation