2020
DOI: 10.1016/j.chemosphere.2020.126973
|View full text |Cite
|
Sign up to set email alerts
|

Facile sealing treatment with stannous citrate complex to enhance performance of electrodeposited Ti/SnO2–Sb electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 53 publications
0
7
0
Order By: Relevance
“…The experiment was conducted in a cylindrical glass reactor (500 mL) with a sludge volume of 400 mL throughout the experiment. A Ti/SnO 2 -Sb [36][37][38][39] mesh electrode was used as the anode, with a titanium mesh as the cathode. Both the cathode plate and anode plate were of an area of 5 cm 2 , while the distance between both plates was 1 cm.…”
Section: Electrochemical Cell Lysis Experimental Setupmentioning
confidence: 99%
“…The experiment was conducted in a cylindrical glass reactor (500 mL) with a sludge volume of 400 mL throughout the experiment. A Ti/SnO 2 -Sb [36][37][38][39] mesh electrode was used as the anode, with a titanium mesh as the cathode. Both the cathode plate and anode plate were of an area of 5 cm 2 , while the distance between both plates was 1 cm.…”
Section: Electrochemical Cell Lysis Experimental Setupmentioning
confidence: 99%
“…Higher electron cloud density means less lattice oxygen and more oxygen vacancies, thus promoting the generation of hydroxyl radicals, which was basically consistent with the information reflected in the LSV curve. The O 1s spectrum of Sb-SnO 2 coating was fitted by several peaks located at about 531 eV (Figure 4(d)), which was ascribed to lattice O (530 eV), surface adsorption oxygen (531 eV), and organic oxygen (533 eV), respectively (Kundu et al 2008;Sun et al 2020aSun et al , 2020bSun et al , 2020c. The peak in the figure is the result of the overlap of the above oxygen.…”
Section: Physicochemical Characterizationmentioning
confidence: 97%
“…The cellular voltage was recorded using a data acquisition system (Agilent, 34970A). The time when the cell voltage was increased to 10 V informed about the anode deactivation due to coating failure (Sun et al 2020a(Sun et al , 2020b(Sun et al , 2020c). The service life was calculated by the following formula: (i actual ¼ 50 mA/cm 2 ):…”
Section: Electrochemical Characterizationmentioning
confidence: 99%
See 2 more Smart Citations