2018
DOI: 10.1016/j.ijbiomac.2018.01.061
|View full text |Cite
|
Sign up to set email alerts
|

Facile preparation and characterization of pH sensitive Mt/CMC nanocomposite hydrogel beads for propranolol controlled release

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
19
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 62 publications
(21 citation statements)
references
References 45 publications
2
19
0
Order By: Relevance
“…With further increase of pH to 7.4, the hydrogenbonding interaction of hydrogel beads disintegrated and the electrostatic repulsion of -COO − within the test hydrogel beads strengthened, which led to the further increase of the swelling ratio. The above information indicated the hydrogel beads had a benign pH-responsive behaviour with an external pH solution, which was also similar to the previous research reports in the literature [50,51].…”
Section: Swelling Properties 361 Effect Of the Pgs Content On Swellingsupporting
confidence: 91%
“…With further increase of pH to 7.4, the hydrogenbonding interaction of hydrogel beads disintegrated and the electrostatic repulsion of -COO − within the test hydrogel beads strengthened, which led to the further increase of the swelling ratio. The above information indicated the hydrogel beads had a benign pH-responsive behaviour with an external pH solution, which was also similar to the previous research reports in the literature [50,51].…”
Section: Swelling Properties 361 Effect Of the Pgs Content On Swellingsupporting
confidence: 91%
“…X-ray diffractometer (X ray analytical Xpert powder diffractometer) was operated and peaks in the form of diffractograms were recorded at a scanning range of 10–100° with an angle of 2θ at a rate of 3°per min. Copper k α was used as radiation source with wavelength 1.542 Å 24…”
Section: Methodsmentioning
confidence: 99%
“…Surface morphology was recorded by using SEM. JEOL Analytical Scanning Electron Microscope (JSM-6490A, JEOL, Tokyo, Japan) was operated at different magnification powers and photomicrographs were captured 24…”
Section: Methodsmentioning
confidence: 99%
“…It is used with pH responsive polymers and explored for their competency in targeted drug delivery 29 , 30 . Pure polysaccharide hydrogels have very low mechanical strength and break quickly in the fluid system resulted in a burst drug delivery 31 . To enhance the mechanical strength, synthetic polymers like polyethylene glycol, polyvinyl pyrrolidone (PVP) and polyvinyl alcohol etc.…”
Section: Introductionmentioning
confidence: 99%
“…To enhance the mechanical strength, synthetic polymers like polyethylene glycol, polyvinyl pyrrolidone (PVP) and polyvinyl alcohol etc. can be added to the hydrogel blends 31 . Blending is the mixing of different polymers to achieve desirable properties 32 , 33 .…”
Section: Introductionmentioning