2010 International Conference on Bioinformatics and Biomedical Technology 2010
DOI: 10.1109/icbbt.2010.5479020
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of microcontroller based multipurpose measuring system with inbuilt data acquisition

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…This system is wholly based on electrical impedance signals of the different frequency applied to get different electrical impedance as the properties of this us. Healthy cells have impedance variation independent of frequency and abdominal cells having frequency dependent on electrical impedance can be identified using EIT [12]. The various method of EIT is neighboring method, opposite _______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 1 Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, India 2 Indian Institute of Technology Delhi, India * Corresponding Author: Email: rameshk.ic.14@nitj.ac.in method, cross method, adaptive, etc.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…This system is wholly based on electrical impedance signals of the different frequency applied to get different electrical impedance as the properties of this us. Healthy cells have impedance variation independent of frequency and abdominal cells having frequency dependent on electrical impedance can be identified using EIT [12]. The various method of EIT is neighboring method, opposite _______________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ 1 Dr. B. R. Ambedkar National Institute of Technology, Jalandhar, India 2 Indian Institute of Technology Delhi, India * Corresponding Author: Email: rameshk.ic.14@nitj.ac.in method, cross method, adaptive, etc.…”
Section: Methodsmentioning
confidence: 99%
“…EIT system uses various methods of electrode arrangement like one ring or more than one ring according to the application [7], but in this work, we used one ring of the electrodes with nail type electrodes. The electrodes may be used nail type, and Ag-Agcl electrode is also used for biomonitoring and ECG, EEG and other application of medical monitoring [12]. The placement of these electrodes on the body, we need some leads, these leads are directly attached to the electrode of the body sites and used to examine electrical movement by monitoring change between them [6].…”
Section: Electrode or Sensormentioning
confidence: 99%
“…In this context, a microcontroller based simple, low cost, lightweight prototype instrumentation impedance measuring device has been designed and developed for bioimpedance measurement and tested and evaluated with the fruit samples. The previous works (Anand, Amit, Ruhi, & Pahuja, 2010;Sagar & Quazi, 2012;Hoja & Lentka, 2009;Puchalski & Brusewitz, 1999;Radil, Pedro, & Cruz Sera, 2005;Hakan et al, 2009;Amer Atta, 2014;Zhang, 2007) are generally found with AD5933 (Analog Devices, Inc.) (Data Sheet, AD 5933, Analog Devices) based impedance converter measuring the complex bioelectrical impedance. Some of the previous works are also developed to use expensive gain-phase detectors like AD8302 (Analog Devices, Inc.) (Data Sheet, AD 5930, Analog Devices).…”
mentioning