2020
DOI: 10.1016/j.msec.2019.110165
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of high strength, antibacterial and biocompatible Ti-5Mo-5Ag alloy for medical and surgical implant applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(21 citation statements)
references
References 59 publications
0
19
0
2
Order By: Relevance
“…Modern beta type alloys contain nontoxic elements and are characterized by high strength, very low elastic modulus, good corrosion resistance, and excellent biocompatibility in comparison to other biometals [4,5]. An examples of modern beta titanium alloys are Ti-5Mo-5Ag [6], Ti-xMo (x-23%-35wt.%) [5,7], Ti14Zr16Nb [4], Ti23Zr25Nb [4], Ti-6Al-2Nb-2Ta-1Mo [8], Ti-15Mo-Zr [9]. It is worth mentioning that a great effort was put into the research and development of Ti-Mo alloys because of their surgical application [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…Modern beta type alloys contain nontoxic elements and are characterized by high strength, very low elastic modulus, good corrosion resistance, and excellent biocompatibility in comparison to other biometals [4,5]. An examples of modern beta titanium alloys are Ti-5Mo-5Ag [6], Ti-xMo (x-23%-35wt.%) [5,7], Ti14Zr16Nb [4], Ti23Zr25Nb [4], Ti-6Al-2Nb-2Ta-1Mo [8], Ti-15Mo-Zr [9]. It is worth mentioning that a great effort was put into the research and development of Ti-Mo alloys because of their surgical application [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…For the viability experiment, a common step is to rinse the substrates to remove non-adhered or weakly-adhered bacteria from the surface before conducting quantication test such as live dead analysis or colony counting. 31,33,37,38,40,45,47,51,53,55,56,59,63,[66][67][68][69][70][71][72][73][74][75][76][77][78][79][80][81][82][83][84][85] Commonly used rinsing methods are summarised in Table 1. Strikingly, the volumes or owrates used in the rinsing step of these studies are unspeci-ed, and the effect of stresses exerted on the loosely attached bacterial cells have not been accounted for.…”
Section: Rinsing Substrate For Removing Non-adhered Bacteriamentioning
confidence: 99%
“…Bacterial infection has been indicated as one of the main factors in the failure of metallic implants [102]. β-Ti alloys have been widely used in medical and surgical implants, but they are currently facing the challenge of implant-related infections [83]. Hence, it is crucial to improve the antibacterial property of the β-Ti alloys.…”
Section: Biological Response 61 Antibacterial Propertymentioning
confidence: 99%