2019
DOI: 10.1016/j.measurement.2019.106867
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of graphene/azobenzene-perylene diimide derivative modified electrochemical sensors for the dopamine detection based on full factorial experimental design

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6

Relationship

3
3

Authors

Journals

citations
Cited by 16 publications
(3 citation statements)
references
References 23 publications
0
3
0
Order By: Relevance
“…graphene/P 4 SAc, ZnO-rGO, MnO 2 /MWCNT, and MWCNT-COOH/Poly(TB)-based DA sensors. (30)(31)(32)(33) Although the DA sensor based on Cu x O/ERGO/Au (34) has an even wider linear range and a smaller LOD than those in the present work, oxygen gas must be introduced during the electrochemical deposition process for the fabrication of the Cu 2 O/CuO/ERGO nanocomposite, which makes the fabrication process inconvenient. Moreover, the stability of the DA sensor in the present work is higher.…”
Section: Continuous Detection Of Da By Lsvmentioning
confidence: 81%
“…graphene/P 4 SAc, ZnO-rGO, MnO 2 /MWCNT, and MWCNT-COOH/Poly(TB)-based DA sensors. (30)(31)(32)(33) Although the DA sensor based on Cu x O/ERGO/Au (34) has an even wider linear range and a smaller LOD than those in the present work, oxygen gas must be introduced during the electrochemical deposition process for the fabrication of the Cu 2 O/CuO/ERGO nanocomposite, which makes the fabrication process inconvenient. Moreover, the stability of the DA sensor in the present work is higher.…”
Section: Continuous Detection Of Da By Lsvmentioning
confidence: 81%
“…Moreover, the products that are obtained after the oxidation of these compounds can be accumulated on the electrode surface causing damages like decrease in sensitivity and reproducibility . For overwhelming these drawbacks, new strategies like centri‐voltammetry have been developed or various electrode modification techniques have been applied …”
Section: Introductionmentioning
confidence: 99%
“…Full factorial experimental design works in an experiment which has two or more factors. By taking the upper and lower limits of our factors, experimental design method provides set of experiment using all the possible combinations of our limits and optimizes the factors to their optimal conditions [30, 31].…”
Section: Introductionmentioning
confidence: 99%