2010
DOI: 10.3379/msjmag.1006r003
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of Co-Pt Dot Array with 1 Tdot/in2 for Bit Patterned Media by Low Energy Ion Etching

Abstract: Dot arrays of Co-Pt with a dot density of 1 Tdot/in 2 were fabricated using electron beam writing. Low-energy ion etching was used to prevent the dots from deteriorating the magnetic properties. We found from the magnetic properties measured using x-ray magnetic circular dichroism that etching with low-energy ions not only caused little damage to the magnetization but also that the anisotropy field of the dots resulted in high coercivity. These results demonstrate the effectiveness of etching with low-energy i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…This capability has been used to directly evaluate the magnetic properties of bit-patterned media. 167,168,[171][172][173] Bit-patterned media 174) was proposed as a new scheme for recording information on magnetic media with ultra-high density data storage. Recording on isolated magnetic dots of perpendicular anisotropy would greatly improve the thermal stability and could reduce the reading noise compared to the continuous granular media presently in practical use.…”
Section: Micro Xmcd Magnetometry In Bit-patterned Mediamentioning
confidence: 99%
See 1 more Smart Citation
“…This capability has been used to directly evaluate the magnetic properties of bit-patterned media. 167,168,[171][172][173] Bit-patterned media 174) was proposed as a new scheme for recording information on magnetic media with ultra-high density data storage. Recording on isolated magnetic dots of perpendicular anisotropy would greatly improve the thermal stability and could reduce the reading noise compared to the continuous granular media presently in practical use.…”
Section: Micro Xmcd Magnetometry In Bit-patterned Mediamentioning
confidence: 99%
“…2 ), 172) to verify the controllability of the magnetic switching field widths by introducing the inter-dot exchange coupling, and to determine the intrinsic contribution to the switching field width caused by the distribution of structural and magnetic properties of each dot. 173) In 2011, the XMCD microprobe at SPring-8 BL39XU was upgraded with the reduction in the focused beam size to 100 nm.…”
Section: Micro Xmcd Magnetometry In Bit-patterned Mediamentioning
confidence: 99%