2020
DOI: 10.1177/2472630319870126
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a Three-Layer PDMS Pneumatic Microfluidic Chip for Micro Liquid Sample Operation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3
2

Relationship

2
3

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 29 publications
0
4
0
Order By: Relevance
“…The research of Bong developed a pressure-driven control system that enables rapid and precise manipulation of complex microflows and further explored its utility in continuous-and pulsed-flow microfluidic procedures for the synthesis and analysis of microparticles [19] . Prior studies found that simulation analysis and experimental research on the performance of the on-chip pneumatic micro actuator of a pneumatic microfluidic chip, including the simulation analysis of the volume and pressure change process in the charging and exhaust process of the actuated chamber, and observed the liquid flow characteristics controlled by air pressure with a type of microscope and verified its working reliability [20][21][22] . Previous studies, both experiments and simulations about pneumatic micro actuators, have focused on influencing factors of air pressure fluctuation, air chamber geometries, or air pressure on the deformation of actuated membranes.…”
Section: Nomenclature E(t)mentioning
confidence: 98%
“…The research of Bong developed a pressure-driven control system that enables rapid and precise manipulation of complex microflows and further explored its utility in continuous-and pulsed-flow microfluidic procedures for the synthesis and analysis of microparticles [19] . Prior studies found that simulation analysis and experimental research on the performance of the on-chip pneumatic micro actuator of a pneumatic microfluidic chip, including the simulation analysis of the volume and pressure change process in the charging and exhaust process of the actuated chamber, and observed the liquid flow characteristics controlled by air pressure with a type of microscope and verified its working reliability [20][21][22] . Previous studies, both experiments and simulations about pneumatic micro actuators, have focused on influencing factors of air pressure fluctuation, air chamber geometries, or air pressure on the deformation of actuated membranes.…”
Section: Nomenclature E(t)mentioning
confidence: 98%
“…Additionally, PDMS demonstrates hydrophobic characteristics that can be used to regulate fluid flow inside the microfluidic device [72]. The hydrophobic properties of PDMS make it easier for well-defined channels and droplets to develop, providing fine-grained control over the transport of samples and reagents [73].…”
Section: (C)mentioning
confidence: 99%
“…2) of PAH-chip design and fabrication and cell seeding on the device so that any researchers without an engineering background can prepare the chips, grow PAH cells, study the PAH pathophysiology, and screen anti-PAH drugs. There are several published protocols on polydimethylsiloxane (PDMS)-based chips are available [13][14][15][16][17][18][19][20][21][22][23] , but our protocol is different in terms of application of the device and the depth of the details. Moreover, the published protocols lack details, but here we have added every detail in each step to prepare PDMS chips in studying the pathophysiology of PAH.…”
Section: Introductionmentioning
confidence: 99%