2022
DOI: 10.1016/j.bioadv.2022.212972
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication of a mimetic vascular graft using melt spinning with tailorable fiber parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 9 publications
(17 citation statements)
references
References 58 publications
0
17
0
Order By: Relevance
“…Numerous studies have explored methods for inducing the circumferential alignment of SMCs in vitro. , Many of these studies rely on seeding SMC on surfaces with circumferentially aligned microgrooves that guide cellular alignment. , Nevertheless, these techniques are often slow, and developing 3D layers of circumferentially aligned cells remains difficult. Using mesenchymal stromal cells and circumferentially aligned fibers, researchers achieved alignment of smooth muscle cell-like layers along the microgrooves .…”
Section: Resultsmentioning
confidence: 99%
“…Numerous studies have explored methods for inducing the circumferential alignment of SMCs in vitro. , Many of these studies rely on seeding SMC on surfaces with circumferentially aligned microgrooves that guide cellular alignment. , Nevertheless, these techniques are often slow, and developing 3D layers of circumferentially aligned cells remains difficult. Using mesenchymal stromal cells and circumferentially aligned fibers, researchers achieved alignment of smooth muscle cell-like layers along the microgrooves .…”
Section: Resultsmentioning
confidence: 99%
“…The fiber diameter was 31.6 ± 3.9 μm, and it was not affected by the printhead speed. Fiber diameter can also be modified by changing the rotational speed of the collector, as demonstrated in an earlier work . In this study, this parameter was kept constant at 1060 rpm.…”
Section: Resultsmentioning
confidence: 99%
“…Melt spinning, the technique used in this and our previous study, is simple, requires low “technological” equipment, is versatile in the diameter of the tubes produced, and possesses the ability to control fiber alignment in the circumferential axis. Despite its many benefits, it is not a widespread technique for the fabrication of tubular scaffolds. , In a recent publication, Zhi and colleagues described the fabrication of scaffolds in a similar fashion to the one described here .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…To determine the stiffness of the EHM ring, mechanical analysis was performed using an Electroforce-3200 Series III multiaxial tensile tester (TA Instruments, Asse, Belgium) combined with a 1000 gf (10 N) load cell (1 kg/cm 2 ), as previously described [ 36 , 37 ]. Test setups and data acquisition were directed through the WinTest 7 operational software (TA Instruments).…”
Section: Methodsmentioning
confidence: 99%