2012
DOI: 10.1590/s0103-50532012000600011
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication, characterization and analytical performance of the hydroxylamine sensor based on an oracet blue multi-walled carbon nanotubes film deposited on an electrode surface

Abstract: Neste trabalho, a oxidação eletrocatalítica de hidroxilamina em um eletrodo de carbono vítreo modificado com "oracet blue" e nanotubos de carbono de paredes múltiplas (OBMWCNT-GCE) foi estudada. O potencial de pico de hidroxilamina em superfície OBMWCNT-GCE desloca em cerca de 320 e 335 mV para valores negativos, em comparação com aqueles em superfície MWCNT e superfície GCE ativada. Os parâmetros cinéticos para a oxidação de hidroxilamina na superfície modificada do eletrodo foram determinados por medidas de … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2013
2013
2020
2020

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 10 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…17,18 The chemical structures of the OB and its proposed electroactive reaction are shown in Fig. In Previous reports, Zare and his colleagues developed an OB modified glassy carbon electrode for the simultaneous detection of dopamine, ascorbic acid and uric acid.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…17,18 The chemical structures of the OB and its proposed electroactive reaction are shown in Fig. In Previous reports, Zare and his colleagues developed an OB modified glassy carbon electrode for the simultaneous detection of dopamine, ascorbic acid and uric acid.…”
Section: Introductionmentioning
confidence: 99%
“…In both cases, OB showed great promise and exhibited a potent and persistent electrocatalytic behaviour for use as an electroactive compound. 17,18 The chemical structures of the OB and its proposed electroactive reaction are shown in Fig. 1.…”
Section: Introductionmentioning
confidence: 99%
“…The dynamic range and the detection limit of the recently reported modied electrodes are shown in Table 2. 14,[31][32][33][34][35][36][37][38]47,[49][50][51][52][53][54][55][56][57][58][59][60] As it can Paper be seen, the capabilities of the proposed sensor are superior in most cases than the others. Using the modied electrode, the relative standard deviation (RSD) corresponding to 10 replicate measurements of 100.0 mmol L À1 hydroxylamine was 1.1%.…”
Section: Differential Pulse Voltammetric Determination Of Hydroxylami...mentioning
confidence: 99%
“…30 In electrochemical methods, various mediators have been used for hydroxylamine determination. For example, electrodes modi-ed with mediators of nickel hexacyanoferrate-carbon ceramic, 31 an indenedione derivative, 32 coumestan derivatives, 33 rutin, 34 alizarin red S, 35 ruthenium oxide nanoparticles, 36 chlorogenic acid, 37 and Oracet blue 38 have been earlier used for the determination of hydroxylamine. The modied electrodes have advantages and limitations.…”
Section: Introductionmentioning
confidence: 99%
“…The present work was conducted based on the second peak potential at 540 mV. Based on preparation methods of the OB-modified electrodes reported in the literature [16][17][18], the present work describes the utilization of a oracet blue/silver-nanoparticles/graphen-oxide-modified screen-printed electrode (OB/SNPs/GO/SPE) as an electrocatalyst for the oxidation of STR. Additionally, the successful determination of STR in the presence of OTC in real samples with the prepared modified electrode is described.…”
Section: Introductionmentioning
confidence: 99%