2018
DOI: 10.3390/mi9090455
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication and Characterization of PZT Fibered-Epitaxial Thin Film on Si for Piezoelectric Micromachined Ultrasound Transducer

Abstract: This paper presents a fibered-epitaxial lead zirconate titanate (PZT) thin film with intermediate features between the monocrystalline and polycrystalline thin films for piezoelectric micromachined ultrasound transducer (pMUT). The grain boundaries confirmed by scanning electron microscopy, but it still maintained the in-plane epitaxial relationship found by X-ray diffraction analyses. The dielectric constant (εr33 = 500) was relatively high compared to those of the monocrystalline thin films, but was lower th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 20 publications
(10 citation statements)
references
References 42 publications
(50 reference statements)
0
10
0
Order By: Relevance
“…Thao et al in 2018 replaced monocrystalline/polycrystalline PZT with fibered-epitaxial PZT to improve piezoelectric properties of PZT thin-films used in pMUT fabrication, the reported results were promising in terms of offering more design flexibility and improved signal-to-noise ratio for the pMUT's [51].…”
Section: Historical Development Of Pmut'smentioning
confidence: 99%
“…Thao et al in 2018 replaced monocrystalline/polycrystalline PZT with fibered-epitaxial PZT to improve piezoelectric properties of PZT thin-films used in pMUT fabrication, the reported results were promising in terms of offering more design flexibility and improved signal-to-noise ratio for the pMUT's [51].…”
Section: Historical Development Of Pmut'smentioning
confidence: 99%
“…Architecture (c), in which the PZT layer is patterned on top of the membrane, is an improved version of the one that was used by Thao et al [24]. Unlike the work of Thao et al, we could successfully pattern the PZT without any crack or delamination of the PZT layer.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the product of the sensitivities can be described by , which is denoted as the figure of merit for a pMUT [ 80 ]. Since larger give rise to a smaller maximum range error or larger maximum range according to Equation (10), researchers have been working on choosing different piezoelectric materials and strategies to enhance by increasing the absolute value of or decreasing in order to enlarge the maximum range of pMUT rangefinders [ 81 , 82 , 83 ].…”
Section: Advancements Of Pmut Rangefinders Based On Improvements Of P...mentioning
confidence: 99%