Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter

Abstract: A : A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1 cm 2 ) and tungsten absorbers (each of one radiation length), has been constructed for measurement of electromagnetic showers over a large energy range. The signal from each of the silicon pads is readout using an ASIC with a dynamic range from −300 fC to +500 fC. Another ASIC with a larger dynamic range, ±600 fC has been used as a test study. The calorimeter was exposed to p… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 31 publications
(36 reference statements)
0
4
0
Order By: Relevance
“…active silicon layers. The primary objective of the FOCAL detector is to provide optimum position and energy resolution of the photons and separate from 0 up to 200 GeV [14,15] of incident energy for the incoming particles. FOCAL consists of two different types of silicon detector layers, high granularity layers (HGL) and low granularity layers (LGL).…”
Section: Jinst 16 P09026mentioning
confidence: 99%
See 2 more Smart Citations
“…active silicon layers. The primary objective of the FOCAL detector is to provide optimum position and energy resolution of the photons and separate from 0 up to 200 GeV [14,15] of incident energy for the incoming particles. FOCAL consists of two different types of silicon detector layers, high granularity layers (HGL) and low granularity layers (LGL).…”
Section: Jinst 16 P09026mentioning
confidence: 99%
“…This plot assures minimal contribution from the FEE chain in the RMS value of figure 9D. A Prototype Si-W sampling type electromagnetic calorimeter was built with 19 layers of alternating 6x6 array of silicon pad detectors and tungsten absorber/converter as a very next step [15]. As shown in figure 11A, the experimental setup was installed at the H6 beamline facility at CERN-SPS [35].…”
Section: Test With Beta Source and High-energy Beammentioning
confidence: 99%
See 1 more Smart Citation
“…In the calorimeter, tungsten as a passive absorber initiates the EM shower, which subsequently progresses along with the depth of the calorimeter with fractional (∼ 2%) energy absorption in the active silicon layers. The primary objective of the FOCAL detector is to provide optimum position and energy resolution of the photons and separate 𝛾 from 𝜋 0 up to 200 GeV [14,15] of incident energy for the incoming particles. FOCAL consists of two different types of silicon detector layers, high granularity layers (HGL) and low granularity layers (LGL).…”
Section: Introductionmentioning