2017
DOI: 10.1002/eqe.2924
|View full text |Cite
|
Sign up to set email alerts
|

Extreme behavior in a triple friction pendulum isolated frame

Abstract: Summary While isolation can provide significantly enhanced performance compared to fixed‐base counter parts in design level or even maximum considered level earthquakes, there is still uncertainty over the performance of isolation systems in extreme events. Researchers have looked at component level stability of rubber bearings and on the effect of moat impact on behavior of structures isolated on general bilinear isolators. However, testing of triple friction pendulum (TFP) sliding bearings has not been done … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
23
0
1

Year Published

2017
2017
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 64 publications
(27 citation statements)
references
References 25 publications
(40 reference statements)
0
23
0
1
Order By: Relevance
“…For horizontal isolation systems, adaptive behavior has been proposed to meet multiple objectives under increasing levels of ground motion excitation (Fenz and Constantinou, 2007, Morgan and Mahin 2010, Yang et al, 2010, Becker et al, 2017, Van Engelen et al, 2016. The adaptability of these systems is derived from the physical configuration or material properties of the systems.…”
Section: Introductionmentioning
confidence: 99%
“…For horizontal isolation systems, adaptive behavior has been proposed to meet multiple objectives under increasing levels of ground motion excitation (Fenz and Constantinou, 2007, Morgan and Mahin 2010, Yang et al, 2010, Becker et al, 2017, Van Engelen et al, 2016. The adaptability of these systems is derived from the physical configuration or material properties of the systems.…”
Section: Introductionmentioning
confidence: 99%
“…Mosqueda et al [11] conducted experiments on a rigid-block frame supported by four bearings on the earthquake simulator platform to evaluate friction pendulum bearings under multiple components of excitation. Becker et al [12] practiced a dynamic unidirectional shake table test of a steel frame isolated with triple friction pendulum bearings, in which the ground motion input was increased until failure occurred in the isolation level.…”
Section: Introductionmentioning
confidence: 99%
“…Over recent decades, the base isolation system has been shown to effectively protect structures and facilities against earthquakes . The friction pendulum system (FPS) isolator is a commonly used base isolation system . A conventional FPS isolator primarily consists of a slider and a sliding surface, which is usually concave shaped.…”
Section: Introductionmentioning
confidence: 99%
“…2,3 The friction pendulum system (FPS) isolator is a commonly used base isolation system. [4][5][6][7] A conventional FPS isolator primarily consists of a slider and a sliding surface, which is usually concave shaped. The gravitational load of the superstructure applied on the FPS isolator can provide a restoring force to reduce the residual displacement of the isolation layer.…”
Section: Introductionmentioning
confidence: 99%