2013
DOI: 10.1016/j.desal.2013.06.008
|View full text |Cite
|
Sign up to set email alerts
|

Extractive concentration of aqueous salt solutions in aqueous two phase systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 10 publications
(14 citation statements)
references
References 39 publications
0
6
0
Order By: Relevance
“…This facilitates the transfer of carboxylic acid molecules into the organic solvent phase, and minimizes solvent leaching (Pratiwi et al, 2015). This practice is known in the literature as "salting out" (Milosevic et al, 2014(Milosevic et al, , 2013. It should be noted that the added electrolyte must not interact with carboxylic acids in such a way that their molecular (undissociated) forms are disturbed.…”
Section: Enhancing Extraction With Salting Outmentioning
confidence: 99%
“…This facilitates the transfer of carboxylic acid molecules into the organic solvent phase, and minimizes solvent leaching (Pratiwi et al, 2015). This practice is known in the literature as "salting out" (Milosevic et al, 2014(Milosevic et al, , 2013. It should be noted that the added electrolyte must not interact with carboxylic acids in such a way that their molecular (undissociated) forms are disturbed.…”
Section: Enhancing Extraction With Salting Outmentioning
confidence: 99%
“…Classical aqueous biphasic systems have already been investigated as extraction/concentration techniques. 27,28…”
Section: Introductionmentioning
confidence: 99%
“…Classical aqueous biphasic systems have already been investigated as extraction/concentration techniques. 27,28 In addition to the more conventional polymer-based systems, in 2003, Gutowski et al 29 demonstrated that hydro-philic ionic liquids (ILs) can also form aqueous biphasic systems by the addition of inorganic salts. After this proof of principle, in the following years it was shown that IL-based aqueous biphasic systems can be formed with organic salts, amino acids, carbohydrates or polymers.…”
Section: Introductionmentioning
confidence: 99%
“…The tube was then placed in a thermotank (DHG-9031A, Shanghai Jinghong Laboratory Instrument Co. Ltd.) at (298 ± 0.1) K for 15 h to achieve thorough dissolution equilibrium. Afterward, the tube was centrifuged for 5 to determine the concentration of naphthalene in the top phase. Each solubility experiment was repeated three times.…”
Section: Determination Of Peg In the Atpsmentioning
confidence: 99%