2014
DOI: 10.1021/ac502575k
|View full text |Cite
|
Sign up to set email alerts
|

Extraction of Rotational Correlation Times from Noisy Single Molecule Fluorescence Trajectories

Abstract: Monitoring single molecule probe rotations is an increasingly common approach to studying dynamics of complex systems, including supercooled liquids. Even with advances in fluorophore design and detector sensitivity, such measurements typically exhibit low signal to noise and signal to background ratios. Here, we simulated and analyzed orthogonally decomposed fluorescence signals of single molecules undergoing rotational diffusion in a manner that mimics experimentally collected data of probes in small molecul… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
20
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
8
1

Relationship

6
3

Authors

Journals

citations
Cited by 14 publications
(21 citation statements)
references
References 41 publications
(61 reference statements)
1
20
0
Order By: Relevance
“…Single molecule linear dichroism analysis was performed using a custom program written in IDL (Interactive Data Language, ITT Visual Information Solutions), as described in detail in Ref. 24. Analysis began with identifying the positions of each single molecule in a band-passed and 500 frames summed image.…”
Section: Discussionmentioning
confidence: 99%
“…Single molecule linear dichroism analysis was performed using a custom program written in IDL (Interactive Data Language, ITT Visual Information Solutions), as described in detail in Ref. 24. Analysis began with identifying the positions of each single molecule in a band-passed and 500 frames summed image.…”
Section: Discussionmentioning
confidence: 99%
“…For single frame rate data, median frame rate was chosen to be ∼ 15 frames per median τ fit and only molecules with (number of frames)/τ fit >2 and trajectory length >10 τ fit were analyzed. Data analysis was performed using IDL software (ITT Visual Information Solutions) as described previously (10,22).…”
Section: Methodsmentioning
confidence: 99%
“…Background intensity, signal-to-background ratio, and camera noise were applied as described previously. 36 A Gaussian fit was performed on the noisy PSF to determine centroid position before stochastic noise was renewed. This process was repeated 2700 times, and a MSD was constructed from the fitted positions, which will differ within localization accuracy.…”
Section: A Monitoring Dynamics During Polymer Film Swellingmentioning
confidence: 99%