1984
DOI: 10.1039/an9840900123
|View full text |Cite
|
Sign up to set email alerts
|

Extraction-atomic-absorption spectrophotometric determination of antimony by generation of its hydride in non-aqueous media

Abstract: A method for covalent hydride generation in a non-aqueous extraction phase is proposed. The hydride generation is carried out in an aliquot of metalcomplex extraction solution by sodium tetrahydroborate(ll1) in N,N-dimethylformamide solution and anhydrous acetic acid. The proposed method gives improved sensitivity, eliminates interferences and enables hydride generation of difficult elements to be carried out. Antimony is extracted by ammonium pyrrolidine-I -carbodithioate into chloroform and after hydride gen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

1985
1985
2002
2002

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 0 publications
0
4
0
Order By: Relevance
“…Extractive separation of Sb with TOPO/i-BuCOMe was combined with pulsed introduction into an air-acetylene flame for the determination of PPM in steels (204), while extraction with ammonium pyrrolidine-l-carbodithioate into chloroform and subsequent hydride generation from this matrix for a final atomic absorption determination has also been reported (25).…”
Section: Antimonymentioning
confidence: 99%
See 2 more Smart Citations
“…Extractive separation of Sb with TOPO/i-BuCOMe was combined with pulsed introduction into an air-acetylene flame for the determination of PPM in steels (204), while extraction with ammonium pyrrolidine-l-carbodithioate into chloroform and subsequent hydride generation from this matrix for a final atomic absorption determination has also been reported (25).…”
Section: Antimonymentioning
confidence: 99%
“…Other spectral methods reviewed were electron microprobe (31,152) and Auger spectroscopy (65,170,176,243,338). Several of these reviews described surface analysis techniques (25,31,60,117,122,125,170,243,245,338,444,482,560).…”
Section: Books and Reviewsmentioning
confidence: 99%
See 1 more Smart Citation
“…Added to these phenomena, important problems of bending of analytical calibration curves of Sb have also been noted previously [20,21]. In these studies, deuterium background correction [22,23,24] or no background correction [25] and peak height measurements have been used. Added to the variety of the systems, very different experimental settings, like a 3.3 nm [23], a 0.7 nm [24] or a 0.2 nm [22] spectral bandwidth coupled to a hollow cathode [24,26] or an electrodeless discharge [22,23] lamp have been also used.…”
Section: Introductionmentioning
confidence: 98%