2017
DOI: 10.3389/fneur.2017.00085
|View full text |Cite
|
Sign up to set email alerts
|

Extracerebral Tissue Damage in the Intraluminal Filament Mouse Model of Middle Cerebral Artery Occlusion

Abstract: Middle cerebral artery occlusion is the most common model of focal cerebral ischemia in the mouse. In the surgical procedure, the external carotid artery (ECA) is ligated; however, its effect on the tissue supplied by the vessel has not been described so far. C57BL/6 mice underwent 1 h of transient MCAO (tMCAO) or sham surgery. Multi-spectral optoacoustic tomography was employed at 30 min after surgery to assess oxygenation in the temporal muscles. Microstructural changes were assessed with magnetic resonance … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
20
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
1

Relationship

6
1

Authors

Journals

citations
Cited by 19 publications
(22 citation statements)
references
References 15 publications
2
20
0
Order By: Relevance
“…Surgeries for tMCAO and sham were performed as described before. 26 Anaesthesia was initiated using 3% isoflurane (Abbott, Cham, Switzerland) in a 1∶4 oxygen/air mixture and maintained at 2%. Before the surgical procedure, a local analgesic (Lidocaine, 0.5%, 7 mg∕kg, Sintectica S.A., Switzerland) was administered subcutaneously (s.c.…”
Section: Transient Middle Cerebral Artery Occlusionmentioning
confidence: 99%
See 1 more Smart Citation
“…Surgeries for tMCAO and sham were performed as described before. 26 Anaesthesia was initiated using 3% isoflurane (Abbott, Cham, Switzerland) in a 1∶4 oxygen/air mixture and maintained at 2%. Before the surgical procedure, a local analgesic (Lidocaine, 0.5%, 7 mg∕kg, Sintectica S.A., Switzerland) was administered subcutaneously (s.c.…”
Section: Transient Middle Cerebral Artery Occlusionmentioning
confidence: 99%
“…A MSOT inVision 128 imaging system (iThera Medical, Germany) was used as described previously. 26 Briefly, a tunable (680 to 980 nm) optical parametric oscillator pumped by an Nd:YAG laser provides 9-ns excitation pulses at a framerate of 10 Hz with a wavelength tuning speed of 10 ms and a peak pulse energy of 100 mJ at 730 nm. Ten arms, each containing an optical fiber bundle, provide even illumination of a ringshaped light strip with a width of ∼8 mm.…”
Section: Multispectral Optoacoustic Tomographymentioning
confidence: 99%
“…Thirteen male C57BL/6J mice (Janvier, France), weighting 20-25 g, 10-weeks-of-age were included in the study. Nine mice underwent tMCAO surgery, and four mice underwent sham-operation as described before [12]. During surgery, mice were given local analgesia and kept under isoflurane anaesthesia, maintaining the body temperature at 36.5 ± 0.5 °C.…”
Section: Animal Modelmentioning
confidence: 99%
“…MMP-activatable probe was incubated with human recombinant MMP-9 or trypsin in vitro and the solution was placed in an agar phantom. A MSOT inVision 128 imaging system (iThera Medical, Germany) was used as described previously [12]. Briefly, a tunable (680-980 nm) optical parametric oscillator pumped by an Nd:YAG laser provides 9 ns excitation pulses at a framerate of 10 Hz with a wavelength tuning speed of 10 ms and a peak pulse energy of 100 mJ at 730 nm.…”
Section: Msot Imaging Of Mmp Activity In Phantom and In Mouse Modelmentioning
confidence: 99%
See 1 more Smart Citation