Abstract:PurposeRadiotherapy has been shown to be an effective for the treatment human glioma and consists of 30 fractions of 2 Gy each for 6-7 weeks in the tumor volume with margins. However. in preclinical studies, many different radiation schedules are used. The main purpose of this work was to review the relevant literature and to propose an external whole-brain irradiation (WBI) protocol for a rat 9L glioma model.Materials and methods9L cells were implanted in the striatum of twenty 344-Fisher rats to induce a bra… Show more
“…Two groups were studied: a control group (n=6) and a treated one (n=8). We set the therapeutic dose at 16 Gy (2x8Gy) as the maximum tolerated dose (MTD) of 18 Gy (3x6Gy) proved to be effective in the 9L-glioma rat model [34].…”
Section: External Beam Radiation and Groupsmentioning
“…Two groups were studied: a control group (n=6) and a treated one (n=8). We set the therapeutic dose at 16 Gy (2x8Gy) as the maximum tolerated dose (MTD) of 18 Gy (3x6Gy) proved to be effective in the 9L-glioma rat model [34].…”
Section: External Beam Radiation and Groupsmentioning
“…1A-B) [16,[60][61][62][63]. Bolus material or acrylic plates may be used to assure proper dose build up [60,61] or to shift the depth dose curve of an electron beam [63].…”
Section: Linear Acceleratormentioning
confidence: 99%
“…Image courtesy of Gabriel Charest; D: Tongue irradiation of a mouse using an orthovoltage X-ray unit [97]. Image courtesy of Wolfgang Dörr. accelerator, which are the multi-leaf-collimator (MLC) and electron applicators [16,[60][61][62][63]. Additionally, a customised block inserted into the accessory holder at the gantry or electron aperture made from MCP alloys (MCP Group, Tilly, Belgium) may be utilised [56][57][58].…”
“…Th e simultaneous irradiation of more than one rat was earlier reported by Vinchon-Petit et al (2010), but that was not a conformal method: the whole brains of four animals were treated with uniform 15 ϫ 15 cm radiation fi elds at a source-axis distance of 100 cm. In our own previous work, we achieved conformal, simultaneous irradiation limited to one region with the use of a special immobilization device and a BrainLab stereotactic system including a micro-multileaf collimator, but the frontal lobe Figure 7.…”
Section: Partial Rat Brain Irradiation 651mentioning
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.